Laserfiche WebLink
i <br />� '` � . � - � <br /> ` Manual S Com liance Re ort Job: 1791A sf ADS <br /> p p Date: 10/13/2017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> I ' • - • � <br />', For: Lennar Homes <br /> • • • • . <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 23267 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB 77.3°F Latent gain: 4075 Btuh Entering coil WB 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 27343 Btuh <br /> Indoor RH: 50°/a Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230'`++TDR <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 25500 Btuh 110% of load <br />' Latent capacity: 4500 Btuh 110% of load <br /> Total capacity: 30000 Btuh 110% of load SHR: 85°/a <br /> . • . <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 25706 Btuh Entering coil DB• 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR <br /> Actual airflow: 1000 cfm <br /> Output capacity: 26000 Btuh 101% of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1000 cfm <br /> I Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> i • <br />�, <br /> Meets are all requirements of ACCA Manual S. <br /> ,� wri htsoft° 2017-Oct-1313:36:39 <br /> 9 Right-Suite�sl Universal 2017 17.0.23 RSU05714 Page 1 <br /> �'� ...CBA27UHE AH's11791A sf ADS template 2.Ston.rup Calc=MJ8 Front Door faces:NW <br /> I <br />