Laserfiche WebLink
.. = � • <br /> FORM R405-2014 - � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1791 Bi sf ADS Builder Name: Lennar Homes 0109 <br /> street: 3156 Moulden Hollow Drive Permit Office: Cl of Zephyrhills <br /> City,State,Zip: ,FL, Permit.Number ��l[3 <br /> owner: Lennar Homes Jurisdiction: 611 00 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft� <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftz <br /> 3. Number of units,if multiple family 1 �,N�q R_ ftZ <br /> 4. Number of Bedrooms 4 d•N�p` R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817 0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1817.00 ftZ <br /> 6. Conditioned floor area above grade(ft� 1817 b.N/A R= ft2 <br /> : <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl, U=0.54 87.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor. Dbl,U=0.56 33.33 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ff2 15.Credits Pstat <br /> Total Proposed Modified Loads: 58.13 pASS <br /> Glass/Floor Area: 0.079 - <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 'Ck1E Sx" <br /> 0�- �TF " <br /> this calculation a're in compliance with the Florida Energy specifications covered by this ��� '"_�� � p <br /> Code. calculation indicates compliance �'s�r,,,'°�� `_'�a,.�'R+. . <br /> �"� �" with the Florida Energy Code. h-.r�rrr"r�°%:�':`_�`:.?;:�'-�'•`•r,�O <br /> PREPARED BY: �7�Ve�l�,l'j�Yl Before construction is completed "" "` � <br /> DATE. this building will be inspected for � ,�j��r- -- -� O <br /> ��1'' � � <br /> compliance with Section 553.908 * �. ..- - _ � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� <br /> with the Florida Energy Code. �G'O�' �� <br /> iN�., <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE. DATE: `� <br /> - Compliance requires certification by the ir handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance wit R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/9/2017 7�16 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 I <br />