My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19139
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19139
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 9:42:05 AM
Creation date
9/20/2018 9:40:36 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-19139
Building Department - Name
LENNAR HOMES LLC
Address
6465 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, �� <br /> FORM�R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2421A sf ADS Builder Name: Lennar Homes 0401 <br /> street: 6465 Paden Wheel Street Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Pertnit Number <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ftz <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 2421.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2421 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11.Ducts R ft2 <br /> 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 <br /> a. U-Factor� Dbl,U=0.54 140.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 64.00 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 26.67 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> 8. FloorTypes (2421.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF'0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2421.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= �Z 15.Credits Pstat <br /> Glass/Floor Area. 0.095 Total Proposed Modified Loads: 77.04 pASS <br /> Total Baseline Loads: 77.37 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _� Of.T13E;SxA�;�_-,, <br /> � :-,` <br /> this calculation are in compliance with the Florida Energy specifications covered by this y'�•�y ,r = ;;; O <br /> fi_. <br /> Code. calculation indicates compliance k3,i;,''' , ':�=.-;.,� .+s+. <br /> � _r '=z;.. „ � <br /> �aVe 'J�G� with the Florida Energy Code. ti .�rrrr�'%:%:=:_:��<;:�'�`�, � , <br /> PREPARED BY: ���� ���� � <br /> Before construction is completed c`� - �-�r ' '�� ►�. <br /> DATE: this building will be inspected for � �"� '�� : C7 <br /> � � , <br /> compliance with Section 553.908 *, -=�' • �' ;- -�. <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. .� � <br /> Y fY 9� 9 P �G, ��a`� .= <br /> with the Florida Energy Code. �D�y�r�� ,_- <br /> OWNER/AGENT: BUILDING O FIC AL: <br /> DATE. �TE: � � <br /> - Compliance requires certification by the air handle unit manufacturer that the air hand er enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/11/2017 11 46 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.