My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19140
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19140
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 9:44:37 AM
Creation date
9/20/2018 9:44:35 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19140
Building Department - Name
LENNAR HOMES LLC
Address
3144 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• r 1 <br /> Manual S Com liance Re ort Job: 1941B sf ADS <br /> p p Date: 10/13/2017 <br /> Entire House � BY: oa�e <br /> Bayonet Plumbing Heating and Air <br /> ' • - • � <br /> For: Lennar Homes <br /> � • • • • ' <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26132 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4171 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB. 75.0°F Total gain: 30303 Btuh , <br /> Indoor RH 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29070 Btuh 111% of load <br /> Latent capacity: 5130 Btuh 123% of load <br /> Total capacity� 34200 Btuh 113% of load SHR: 85% <br /> • • � <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 28628 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR <br /> Actual airflow� 1200 cfm <br /> Output capacity: 32800 Btuh 115% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets are all requirements of ACCA Manual S <br /> ^.� V{/1�1 htsoft° 2017-Oct-1313:23:14 <br /> 9 Right-Suite�l Universal 2017 17.0.23 RSU05714 Page 1 <br /> �� ...th CBA27UHE AH's\1941B sf ADS temptate 3ton.rup Calc=MJ8 Front Door faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.