Laserfiche WebLink
".J r <br /> Pro ect Summar Job: <br /> -� wrightsoft� � � Date: Oct 10,2014 <br /> � Entire House By� <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' � • <br /> For: DR Horton/Express <br /> Lot 1 Blk 6 Sifverado Ranch, Zephyrhills, FL <br /> Notes: - <br /> � - • • • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 30 °F Design TD 16 °F <br /> Daily range - L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing , <br /> Structure 20520 Btuh Structure 23527 Btuh <br /> Ducts 6629 Btuh Ducts 8990 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) , (none) <br /> Humidification 0 Btuh Blower 0 Btuh - <br /> Piping 0 Btuh <br /> Equipment load 27149 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 32517 Btuh <br /> Method simp�ified Latent Cooling Equipment Load Sizing <br /> Construction quality Semrtight <br /> Fireplaces 0 Structure 2674 Btuh <br /> Ducts 1469 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2 2659 2651 Equipment latent load 4144 Btuh <br /> Volume�ft3) 22094 22094 <br /> Air changes/hour 0.22 0.11 Equipment total load 36660 Btuh <br /> Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR 3.6 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042#***A Cond CH14NB042****A <br /> AHRI ref Coil FB4CNP042 <br /> AHRI ref _ <br /> Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER-� - <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output 38500 Btuh @ 47°F Latent cooling - 10250 Btuh <br /> Temperature rise 26 °F Total cooling 41000 Btuh <br /> Actual air flow 1367 cfm Actuaf air flow 1367 cfm <br /> Air flow factor 0.050 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0.56 in H20 Static pressure 0.56 in H20 <br /> Space thermostat Load sensible heat ratio 0.89 <br /> -Capacity balance point=31 °F <br /> -Backup: - � <br /> Input=9 kW, Output= 29290 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> � wri htsoft@ 2017-Oct-3012:43:11 <br /> �� 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 <br /> \Wrightsott'Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces: N <br />