Laserfiche WebLink
TFP11�0 � <br /> Page 4 of 6 <br /> Frame Sprinkler Finish <br /> K Type Ra ng Color Natural Chrome Lead Wax Wax Over <br /> Code Brass Plated Coated Coated Lead Coated <br /> Pendent(TY3211) 165°F(74°C) Unpainted 1 2 3 <br /> and 212°F(100°C) White 1,2,3,5 <br /> 5.6 Upright(TY3111) <br /> 1/2" 280°F(138°C) Blue 1,2 4 N/A <br /> NPT <br /> Recessed Pendent 165°F(74°C) Unpainted 1,2,3,5 <br /> (TY3211 w/Style 20) 212°F(100°C) White 1,2,3,5 N/A <br /> 165°F(74°C) Unpainted <br /> 1,2,3 <br /> Pendent(TY4211) 212°F(100°C) White 1,2,3 <br /> 280°F(138°C) Blue 1,2 4 N/A <br /> 8.0 165°F(74°C) Unpainted <br /> 3/4" 1,2,3 <br /> NPT Upright(TY4111) 212°F(100°C) White 1,2,3,5 <br /> 280°F(138°C) Blue 1,2 4 N/A <br /> Recessed Pendent 165°F(74°C) Unpainted <br /> (TY4211 w/Style 30) 1�2�5 N/A <br /> 212°F(100°C) White <br /> Pendent(TY4911) '165°F(74°C) Unpainted 1,2,3 <br /> and 212°F(100°C) White 1,2,3,5 <br /> 8�� Upright(TY4811) <br /> I 1/2" 280°F(138°C) Blue 1,2 N/A <br /> N PT <br /> Recessed Pendent '165°F(74°C) Unpainted <br /> (TY4911 w/Style 20) 1�2 N/A <br /> 212°F(100°C) White <br /> OTES: <br /> UL Listed <br /> . C-UL Listed <br /> . FM Approved <br /> . FM Approved for maximum 150°F(68°C)ambient temperatures <br /> . LPCB Approved(LPCB Ref.No.094a/03) <br /> N/A:NotAvailable <br /> TABLE A <br /> LABORATORY L/STINGS AND APPROVALS <br /> After installation, the sprinkler color coded wax is to be used, and Step C. After the ceiling has been <br /> wrench flats and frame arms must retouching of wrench flats and frame installed or the finish coat has been <br /> be inspected and the wax coating arms is only permitted at the time applied, slide on the Style 20 or 30 <br /> retouched (repaired) whenever the of initial sprinkler installation. With Closure over the Series TY-L Sprin- <br /> coating has been damaged and bare tf►e steel rod heated as previously kler and push the Closure over the <br /> metal is exposed.The wax coating on described, touch the rod to the area Mounting Plate until its flange comes <br /> the wrench flats can be retouched by requiring additional wax with the rod in contact with the ceiling. <br /> gently applying a heated 1/8 in. diam- angled downward, and then touch the <br /> eter steel rod to the areas of wax that wax stick to the rod approximately one- � <br /> have been damaged, to smooth it half inch away from the area requiring <br /> back over areas where bare metal is retouching. The wax will melt and run <br /> exposed. down onto the sprinkler. <br /> Series TY-L Recessed Pendent <br /> � Sprinklers Installation <br /> Only retouching of the wax coating The Series TY-L Recessed Pendent <br /> applied to the wrench flats and frame Sprinklers must be installed in accor- <br /> arms is permitted, and the retouching dance with this section. <br /> is to be performed only at the time of Step A. After installing the Style 20 <br /> the initial sprinkler installation. or 30 Mounting Plate, as applicable, <br /> The stee/rod should be heated only over the sprinkler threads and with <br /> to the point at which it can begin to pipe thread sealant applied to the pipe <br /> melt the wax,and appropriate precau- threads,hand tighten the sprinkler into <br /> tions need to be taken, when handling the sprinkler fitting. <br /> the heated rod, in order to prevent the Step B. Tighten the sprinkler into the <br /> installer from being burned. sprinkler fitting using only the W Type <br /> If attempts to retouch the wax coating 10 Recessed Sprinkler Wrench (Ref. <br /> with complete coverage are unsuc- Figure 8).With reference to Figure 1,2, <br /> cessful,additional wax can be ordered or 3,the W Type 10 Recessed Sprinkler <br /> in the form of a wax stick (the end of Wrench is to be applied to the sprinkler <br />' which is color coded).Only the correct wrenching flanges. <br />