Laserfiche WebLink
. , <br /> • 1 <br /> II � <br /> , � � <br /> , � o <br /> • . . . . � � <br />, . � . <br /> � 0 � . <br /> ��i m <br /> ���� <br /> ' r�s�- �,,� <br /> �T-qq�.{�. <br /> 'PL9Ff <br /> — ,-: .� <br /> -- - - � ,..s 0' - . <br /> _ � _ k'��, �� I � _ <br /> � �r+ d I <br /> 5(IP, ;11�. 6100EL�f011 , <br /> — 3 <br /> J�Cs <br /> t. arLi.w. �.3' _ <br /> •The AGF Manufacturing Inc. Model 1011A TESTaNDRA1N�matches all the features and benefits of our Model <br /> 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire <br /> sprinkler system,with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. <br /> •The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed <br /> on all gridded systems and downstream of all pressure reducing valves(see reverse). <br /> •The Model 1011A TESTaNDRA1N�is a compact single handle ball valve which includes a tamper resistant <br /> test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. <br /> •Available in a full range of sizes from 3/a" to 2" NPT and BSPT, with all specifiable orifice sizes 3/e" (2.81n,'/s" <br /> (4.2f�, �/2" (5.61n, "/sz" (8.01�, 5/s" (11.2K, ELO), 3/a" (14.OK, ESFR), and K25 as required by NFPA 13, 2007 Edi- <br /> tion (see reverse). <br /> •The included UVFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 <br /> PSI. Other pressure settings are available and may be substituted. <br /> � Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- <br /> ficult problem of providing the relief valve with a convenient drainage-piping outlet. <br /> • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. <br /> •A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- <br /> tional alarm activation. <br /> • Repair kits including(1)adapter gasket, (1) ball, (2)valve seats, (1)stem packing, and (1)stem washer are avail- <br /> able for all TESTaNDRA1N�valves.Valve and orifice size must be specified when ordering. <br /> NOTE:It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and <br /> closing of the valve.Standard relief valves are required to OPEN in a range of pressure between 90%and•105%of their rating.The valves <br /> are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for main- <br /> tenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve <br /> should NEVER have a shutoff valve or a plug downstream of its outlet. <br /> i � � r � � � � � r � <br />� TESTANDRAIN Is a registered trademark of AGF Manufacturing Ina CS1011A 10/09 <br />