Laserfiche WebLink
BUILDING DROPS FL#: 14218 - <br /> y A Perfect Solution in Every Drop Date: 06/03/2015 <br /> CertificateofAuthorization:29578 Report No: 3744 <br /> Installation: <br /> Refer to Installation Instructions(YKK107)for anchor spacing and more details of the installation <br /> ' requirements. <br /> Design Pressure: <br /> Refer to Installation Instructions(YKK107)for design pressures based on size,configuration, and <br /> glass types. <br /> Equivalence of Test Standards: <br /> Various test standard(s) have been evaluated for differences in test methodology, if any, between tested <br /> editions of the test standards listed below and those editions referenced in the current Florida Building Code. <br /> YKK AP has tested their products to the following test standard edition(s): <br /> 1) ASTM E283-99 <br /> The current Florida Building Code references the following editions of the above mentioned test standards: <br /> 1) ASTM E283-04 <br /> After review of the above mentioned referenced standards and editions, it has been found that no significant <br /> technical changes have been made to the test standards that would affect the results.All referenced <br /> standards have been found to be equivalent.All materials test results meet minimum requirements of the <br /> current Florida Building Code. <br /> Hermes F. Norero, P.E. <br /> Florida No.73778 <br /> Page 4 of 4 <br />