Laserfiche WebLink
, <br /> Job: <br /> -�- wrightsoft� Manual S Compliance Report Date: Oct 10,zo,4 <br /> Entire House Bv: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � � ' • • <br /> For: DR HortoNExpress <br /> Lot 43 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> • • e • o <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 21821 Btuh Entering coil DB: 75.4°F <br /> Outdoor design WB. 77.1°F Latent gain: 2966 Btuh Entering coil WB: 62.7°F <br />' Indoor desi n DB: 75.0°F Total ain: 24787 Btuh <br /> 9 9 <br /> 0 <br /> Indoor RH: 50/o Estimated airflow: 1000 cfm <br />� , <br /> Manufacturer s Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030"""A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23270 Btuh 107%of load <br /> Latent capacity: 3914 Btuh 132%of load <br />, Total capacity: 27184 Btuh 110%of load SHR: 86% <br /> � i 0 <br /> Design Conditions <br />� Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F <br /> o _ <br />, Indoor design DB: 70.0 F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14N6030''""A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25604 Btuh 121%of load Capacity balance: 32 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.6 kW 107%of load Temp. rise: 20 °F <br /> Meets are all requirements of ACCA Manual S. <br /> 1. WI�1 �1tS�ft`� � 2017-Oct-3014:05:31 <br /> �. 9 Right-Suiie�Universal 2017 17.0.21 RSU25554 Page 1 <br /> �'� .on\Wrightsott Files\Express homes\Cali 4EBB.rup Calc=MJS House taces. S <br /> ill , <br />