Laserfiche WebLink
VVEINTRAU� <br /> � INSPECTIONS&FORENSIC,INC. <br /> 3868 Sun City Center Blvd. Ph.813-633-8000 <br /> Sun City Center,Fl.33573 Fx.813-464-8026 <br />� 15' Verify isolation pipe chases installed at plumbing penetrations through X <br /> footing two(2)pipe-sizes greater than penetrating pipe. <br /> 16. Verify that special arching reinforcing steel in footing is installed at pipe X <br /> penetrations per architectural detail <br /> Verify ufer-ground properly sleeved thru footing and Installed in accordance <br /> 17. with permitted plans and FBC;where attached to footing rebar eliminate X <br /> vapor barrier under footer for 20 foot length at connection <br /> 1 g Verify masonry wall dowel installation for size,placement,Location, X <br /> cleazances&size per permitted plans <br /> Comments: <br /> RESULTS <br /> INSPECTION ITEMS NOT CHECKED PASS AND FAIL INDICATES NOT APPLICABLE <br /> Pass <br /> (*)re-inspection required for failed inspections <br /> INSPECTED BY: <br /> Sean Cyr <br /> Inspectors Name <br /> scyr�a weintraubinspections.com <br /> Email address <br /> 813.853.4313 <br /> Phone# <br />