Laserfiche WebLink
; <br /> �, . <br /> • FORM R405-2014 • <br /> FLORIDA ENERGY- EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional-Regulation - Residential Performance Method <br /> Project Name: Aria Elevation D Builder Name: DRH Express Homes <br /> Street: �j����,;_GC' �i�� � i < } Perrnit Office: <br /> City,State,Zip: Zeph hit ,FL,vn��l ���2t� �1 ,v Permit Number: <br /> Owner: �� -1 ���f� Jurisdiction: <br /> Design Location: FL,Tampa � � County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing- New(From Plans) 9. Wall Types(1658.2 sqft.) - Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ftz <br /> b.Frame-Wood,Adjacent R=11.0 286.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 10.Ceiling Types (1672.0 sqft,) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz <br /> 6. Conditioned floor area above grade(ftz) - 1672 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11 Ducts R ftz <br /> 7. Windows(182.0 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 334 <br /> a. U-Factor: Dbl, U=0.34 142.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency- <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.985 ft. <br /> Area Weighted Average SHGC: 0.317 14 Hot water systems <br /> a.Electric Cap:50 gallons <br /> S. Floor Types (1672.0 sqft.) Insulation Area <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz EF.0.950 <br /> b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 56.48 n A�� <br /> Glass/Floor Area: 0.109 Total Baseline Loads: 57.14 rf1 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.��SES�,��,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �� = .; p <br /> Code. calculation indicates compliance �'c+',,,,°''��� z=;',� �,,,� <br /> �.°.o ic" <br /> with the Florida Energy Code. N �rtrrr.':.,'��:;:<::;;..',;��,;,�`�„ o <br /> PREPARED BY: L'N1�- .,,,,�... Before construction is completed � ' � <br /> DATE: i -3o-i� this buildin will be ins ected for � j''' _ ~ ,q; <br /> 9 P t7 _`l,i�- <br /> compliance with Section 553.908 * l�. �' � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ,� _ '. �,S <br /> with the Florida Energy Code. D��¢� <br /> OWNER/AGENT: -����"���' � BUILDING FFICIAL: <br /> DATE: Il , DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> . certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 10/30/2017 11:11 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> i <br />