Laserfiche WebLink
Job: <br /> � -�- wrightsoft� Pro ect Summar � <br /> � y Date: Oct 10,2014 , <br /> Entire House Bv� <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 ' <br /> � � ' � � <br /> For: DR Horton <br /> Lot 2 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br />� � - s � • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 30 °F Design TD 16 °F <br /> Daily range L , <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 16693 Btuh Structure 16219 Btuh <br /> Ducts 3619 Btuh Ducts 5114 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh - <br /> (none) (none) - <br /> Humidification 0 Btuh Blower 0 Btuh , <br /> Piping 0 Btuh <br /> Equipment load 20312 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 21334 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight ` <br /> Fireplaces 0 Structure 2231 Btuh <br /> Ducts 646 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2 1647 1647 Equipment latent load 2877 Btuh <br /> Volume�ft3) 14494 14494 <br /> Air changes/hour 0.26 0.14 Equipment total load 24211 Btuh <br />, E uiv.AVF cfm 63 34 Re . total c acit at 0.75 SHR 2.4 ton <br /> q � ) q aP Y <br />, Heatin E ui ment Summa Coolin E ui ment Summa <br /> J q p rY 9 q p rY <br /> Make Carrier Make Carrier <br />- Trade CARRIER Trade CARRIER <br /> Model CH14NB030*`"`A Cond CH14N6030*'�"A <br /> _ AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER � <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh <br /> Temperature rise 27 °F Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H20 � Static pressure 0 in H20 <br /> - Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=3'1 °F <br /> Backup: . <br /> Input=6 kW, Output=21934 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ,� wri htsoft°� 2017-Oct-30 11:07-43 <br /> �� g Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 <br /> .on\Wrightsoft Files\Express homes\Aria 4EAB.rup Calc=MJ8 House faces: N � � <br />