Laserfiche WebLink
e � � I <br /> l <br /> "FORM 1�405-2014. <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C�NSTR�JCTION <br /> Florida Department of Busir�ess and Professional Regulatian - Residentia] Pe�formance Method <br /> Project Name: /�Aria Elevation D,/t.,, Buiider Name: DRH Expre,�s No es �`�� <br /> Street: Cc�����I/J�.'�{� ��(����j"l-�`C,L,-�-� 1 Permit Office: � (}`��� <br /> Gity,State,Zip. Zephyrhills,FL����� �,,/�,1 Permit Number: )�� � <br /> Owner� '�� �p Jurisdiction: IG 6t� � <br /> Design Location: FL,Tampa �� County:: Pasco(Florida Climafe Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area <br /> 2. Single fami(y or multipfe famiiy Single-family a.Goncrete Blacic-Int Insul,E�erior R=4 1 1372.2�ft2 <br /> b.Frame-Waod,Adjacent R=11.0 286.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft� <br /> 4. Numlaer of Bedrooms 3 d'�lA R= �2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1672.q sqft.) Insulation Area 2 <br /> , a.Under Attic(VentedJ� R=30.0 1672.00 ft <br /> 8, Condi#ioned floar area above grade(ft�} t 672 b.R3lA R= ftz <br /> Conditioned fioor area below grade(ft�) 0 c.N/A R= ft� <br /> 1i.Ducts R ft2 <br /> 7 Windows(182.0 sqft.} Description Area a.Sup:Attic,Fiet:Main,AH:Main 6 334 <br /> a. U-Factor: Dbl,U=0.34 142.00 ft2 <br /> SNGG: SHGC=0.31 - <br /> b. U-�actor dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factar: N1A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N!A ft2 a.Electric Hea2 Pump 28.6 NSPF:8.20 <br /> SHGC• <br /> Area Weighted Average Overhang Depth: 4.985 ft. <br /> Area Weighted Average SIiGC: 0.317 14 Hot wafer systems <br /> 8. Floor Types (1672.0 sqft.) Insulation Area a.E(ectric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-Qn-Grade Edge lnsulafion R=0.0 1672.00 ttz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft� 15.Credits Pstat <br /> Glass/Floor Area: 0.109 Total Proposed Modified Loads: 57.37 ���+t+ <br /> Total Baseline Laads: 57.14 ���� <br /> I hereby certify ihat the plans and specifications covered by Review of the plans and �"�����'�p. <br /> this calculation are in campliance with the Flarida Energy specifications covered by this d = � "�t)�, <br /> i`� `-c:` �+ <br /> Code. calculation indicates compliance - � .�i,, `'' = Y�,���� <br /> with the�(orida Energy Code. � �r�rr,�''�;;:`;::=.;;:;;,.'=��tt� <br /> PREPARED BY: �'M1�-�Qn�,:.. Before constructian is campleted c`� � � '� " � <br /> s4 _._.=I��f <br /> pq��; tn-3o-t7 this bui(ding wili be inspected for � I��°� � <br /> compliance with Section 553.908 * ��' �, <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. .r,�,, � �� <br /> � with the F(arida Energy Cade. �at5�rE'�`� <br /> C3WNERfAGEN�'���="'�r����-�-'V'�..e._--__ BUlL.DING OFFICIA : <br /> DATE: .--ti_�71��1�� �� DATE: <br /> - Comptiance requires certification by the air handter unit manufacturer that#he air handler enciosure qualifies as <br /> certified factary-sealed in accordance with R403.2.2.1, _ <br /> •Compliance requires an Air Barrier and tnsulation Inspection Ghecklist in accordance with R4U2.4.1.1 and an envelope leakage <br /> test report in aacardance with R402.4.1.2. <br /> 1 0/30/201 7 1 1:06 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />