<br /> The following notes appty to the systems outlined herein:
<br /> 1. The roof rystem evaluation herein pertains to above-deck roof components. Roof decks and structurel members shall be in accordance wkh FBC requirements to the satisfaction of the Authority Having Jurisdiction.
<br /> Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
<br /> 2. Unless othenvise noted,fasteners and stress plates for insulation or base sheet attachment shall be as follows.Fasteners shall be of suffitient length forthe following engagements:
<br /> Y Wood Detk: Drill-Tec#12 Fastener or Drill-Tec t114 Fastener wfth Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate,Drill-Tee 3 in.Ribbed Galvalume Plate(Flatj or Drill-Tec AccuTrec Flat Plate or
<br /> Drfll-Tec AtcuTrae Recessed Plate(insulation only),Drill-Tec ASAP 35 or Drill-Tec Heavy Duty ASAP 35.Min.0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
<br /> > Steel Deck: Drill-Tec#12 Fastener,Drill-Tec#14 Fastener or Drill-Tec%HD Fastener with Drill-Tee 3"Standard Steel Plate,Drill-Tec 3"Steel Plate,Drill-Tec 3 in.Ribbed Galvalume Plate(Flatf or Drill-Tec
<br /> AccuTrae Flat Plate or Drill-Tec AecuTrac Recessed Plate(insulatian only).Minimum 0.75-fnth steel penetration,engage the top flute of the steel deck.
<br /> i Structursl Concrete: Drill-Tec p14 Fastener or Drill-Tec CD-10 w(th Drill-Tec 3"Standard Steel Plate,DriIFTec 3"Steel Plate,Drill-Tec 3 in.Ri66ed Galvalume Plate(Flat)or Drill-Tec AccuTrac Flat Plate or Drill-Tec
<br />' AccuTrac Recessed Plate(insulation onty)or Drill-Tec Heavy Duty ASAP 35.Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener
<br /> manufacturers puhlished ins[allation instructions.
<br /> 3. Unless otherwise noted,insulation may be any one layer or combination of polyisotyanurete,polystyrene,wood fiberboard,perlRe,gypsum-based roof board or minersl wool roof board that meets the�,4
<br />� requirements of FA.0 Rule 61G20-3 and is documented as meeting FBC 1505.1 and,forfoam plastic,FBC Chapter 26,when installed wkh the roof cover.
<br /> I Refer to GAF pu6lished installation instructions for details and requirements regarding the use of polystyrene insulation in EverGuard°roofing rystems:
<br /> InsulatWn: HiQh Traffic Anolications: RecorerAoditatiwis:
<br /> l Expanded polystyrene(EPS)meeting or exceeding ASTM C578,Type 1 F�ctruded polystyrene(%PS)meeting or exceeding ASTM C578,TYpe ➢ XPS Fan-Fold Recover Board with plastic facer meeting or exceeding
<br /> II, nominal 1.5 Ib/R2 density and minimum 35 psi compressive IV,minimum 1-inch thick and minimum 25 psi compressive strength. ASTM 678,Type IY,3/8-inch thick and minimum 25 psi compressive
<br /> s[rength. 1 Expanded polystyrene(EPS)wi[h plas[ic(acer meeting or exceeding streng[h.
<br /> � Expanded polystyrene(EPS)with plastic facer meeting or exceeding ASTM C578,Type IX,mtnimum ltinch thick and minimum 75 psi D EPS Recwer Board meeting or ezceeding ASfM C578,Type IV,1/2=
<br /> 0.5TM C578,Type II,nominal 1S Ib/h2 densi[y and minimum 15 psi compressive strength. inch thick and minimum 25 psi compressive strength. �
<br />� compressivestreng[h. ➢ EPS Recover Board wRh plastic facer meeting or exceeding ASTM
<br /> C578,Type II,1/2-inch thick and minimum 15 psi compressive
<br />� streng[h. '
<br /> TOPCOAT�FireOut^'Fire Barrier Coating,VersaShfeld°Fire-Resistant Roof Deck Protection or VersaShield°Solo'"Fire-Resistant Slip Sheet,installed in aaordance with GAF published installation instructions and fire
<br /> resistance cert'fiiwtfon listings,may be used as a non-load-bearing,fire-barrier/slip-sheet component within any rys[em outlined herein. �
<br /> 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete(LWI[)may be substituted for or installed below the rigid insulation board for SystemType GS(mechaniolly attached insulatlon,bonded roof,
<br /> cover),System Type C-2(plate-6onded roof cover)or System Type D(mechanically attached membraneJ,whereby the insulation or membrane fasteners are installed through the LWIC to engage the strudural steel
<br /> or concrete deck. For Type Gl,the top insulation layer shail be that spec�ed in the applicable Table. For Type C-2 or D if the LWIC is installed below,the rigid insulation board may wnsist of min.OS-tnch
<br /> EnergyGuard Polyiso Insulation,EnergyGuard NH Polyiso Insulation,EnergyGuard Ultra Potyiso Insulation,EnergyGuard NH Ultra Polyiso Insulation,EnergyGiurd RA,EnergyGuard RN,EnergyGuard HD Polyiso
<br /> Insulation,EnergyGuard NH HD Polyiso Insulation,EnergyGuard HD Plus Polyiso In:ulation,EnergyGuard NH HD Plus Potyiso Insulation,EnergyGuard RH HD Polyiso Insulatian or Structodek High Densiry Fiber6oard
<br /> Roof Insulation or min.0.25-inch SECUROCK Gypsum-Fiber Roof Board,SECUROCK Glass-Mat Roof Board or Dens Deck.The structural deck shall 6e of equal or greater type,thickness and strength ta the steel and
<br /> concrete deck listings.Roof decks and structurdl members shall be in a�cordance wkh FBC requirements to the satisfaction of the Authority Xaving Jurisdictian.Inad resistance of the roof deck shall be documented
<br /> through proper cod�ed and/or FBC Approval documentation. This is a wind uplift resistance allowance and does not purport to address non-wind-uplik-relatated issues,suth as deck venting or moisture levels
<br /> within the LWIC and the potential effect on overiying components.
<br /> 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 Uanuary 2016).
<br /> 6. Unless otherwise noted,insulation adhesive application rates are as follows.Ribhon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufadurers publ(shed instructions.
<br /> 7% Hot Asphah(HA): Full mopping,25-30 Ibs/square. ,
<br /> > GAF 2-Part Roofing Adhesive(GAF 2-Part): Continuous 25 to 3.5-ineh ribbons,l2-ineh o.e.
<br /> Y LRF Adhesive M(LRF-M): Continuous 0.75 to 1-inch wide ribbons,l2-inch o.e.
<br /> > OlyBond Adhesive Fastener(Clauic): Full coverage,1 gal/square.
<br /> 1 OtyBond 500(OB500): Continuous 0.75 to 1-inch wide ribhons,12-inch o.c.using PaceCart,SpotShot or Canister delivery methods.Note:O/yBond Clossic orOfyBond 500 Green moybe used �I
<br /> in place oJ0(yBond 500.
<br /> � Note:When multiple loyers(sJ of insulation ond/or caverboard are installed in ribban-appiied adhesive,600id joints shall be stoqgered.
<br /> > Note:The marimum edge distonce Jrom the adhesive ribbon to the edge af the insulaSnn boord shall be not/ess than one-hoythe specifed ribbons spodng. I
<br /> Ezterior Research and Design,LLG d/b/a Trinity�ERD Evaluation Report 01506.09.05-R29 for FL5293R27
<br /> Cert�cate of Authorization p9503 6°i Edition�2D17)FBCNON-HVIR EVALUATION Rev(sion 28:10/17/2017 I�
<br /> Prepared by:Robert Niemfnen,PE-59166 GAF EverGuard TPO Single-Pty Roof Mem6rene Systems;(860)7663631 Appendix 1,Page 2 of 94 ��