Laserfiche WebLink
., . . <br /> I �, <br /> FORf�'R405-2014 I <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br />'I . <br /> Project Name: Hayden 2605 Ele D Builder Name: DRH Express Hqmes�� <br /> Street: �j���2 � ���1'��`�I� Permit.Office. ('j Q� ZZP�`�r � <br /> City,State,Zip. Zephyrhills, FL, � Permit Number: �L�� <br /> Owner• � •�'��L.� `nj I� Jurisdiction: (� �((QQp - <br /> Design Location: FL,Tampa �'�''�� � County•• Pasco(Florida-Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(26142 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=11.0 1285.30 ftz <br /> b.Concrete Block-Int Insul, Exterior R=4 1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz <br /> 4. Number of Bedrooms 5 d.N/A R= ftz <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz <br /> 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11. Ducts R ftz <br /> � 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> i a. U-Factor• Dbl,U=0.34 210.00 ftz <br /> SHGC• SHGC=0.31 <br /> b. U-Factor Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br />�I SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a. Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: , <br /> Area Weighted Average Overhang Depth. 1.692 ft. <br /> Area Weighted Average SHGC• 0.315 14.Hot water systems <br /> a. Electric Cap:50 gallons <br /> 8. Floor Types (1541 0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features <br /> b. Raised Floor R=19.0 437.00 ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 77 36 <br /> Glass/Floor Area: 0.096 PASS <br /> Total Baseline Loads� 79.15 <br /> I hereb certif that the lans and s ecifications covered b Review of the lans and '�1�E�7' <br /> Y Y p P Y P �� A�� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,� , _ � O <br /> Code. calculation indicates compliance � �i„'''� `_'�'�� <br /> � <br /> A with the Florida Energy Code. ti rr,ur�'�° `=�=�''����;,�� <br /> PREPARED BY: Before construction is completed c� `�''`��� '���� �'"�� " � <br /> L'Nlr_s(�,�x.i.t 1;: CJ <br /> DATE. u-9-i� this building will be inspected for � ` �,�:;` �, <br /> �� <br /> n <br /> compliance with Section 553.908 * � * <br />� I hereby certify that this building, as designed, is in compliance Florida Statutes. � 1� � �� <br /> with the Florida Ener Code. C�D '�� <br /> 9Y WE <br /> OWNER/AGENT'� BUILDING OFFICIAL: � <br /> DATE: J I / = DATE: �2�L��/� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Gln requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060(�n for whole house. <br /> 1 1/9/201 7 8:54 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />