My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19216
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19216
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 8:52:26 AM
Creation date
9/21/2018 8:52:21 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19216
Building Department - Name
DR HORTON
Address
6552 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Com liance Re„ort J°b: <br /> -�1- �nrriglitsoft� p M Date: Oct 10,20,4 <br /> Entire House By� <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' • • <br /> For: DR Horton/Express , <br /> Lot 13 Blk 6 Silverado, Zephyrhills, FL � <br /> • • • . • <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 29932 Btuh Entering coil DB: 76.4°F <br /> Outdoor design WB: 77.1°F Latent gain: 4144 Btuh Entering coil WB: 63.2°F <br /> Indoor design DB: 75.0°F Total gain: 34075 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042*`*"A+F64CNP042 <br /> Actual airflow: 1367 cfm <br /> Sensible capacity. 32445 Btuh 108%of load <br /> Latent capacity: 6269 Btuh 151%of load <br /> Total capacity: 38714 Btuh 114%of load SHR: 84% <br /> . • • <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70.0°F <br />' Manufacturer's Performance Data at Actual Design Conditions - <br />�i <br />� Equipmenttype: SpIitASHP <br /> Manufacturer: Carrier Model: CH14NB042*'*'`A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37299 Btuh 137%of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br />� Backup equipment type: Elec strip <br />, Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 8.6 kW 108%of load Temp. rise: 18 °F <br /> Meets are all requirements of ACCA Manual S. <br /> .� wri htsoft'` 2017-Nov-09 08:56:32 <br /> ^, 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 <br /> � \Wrightsoft FileslE�ress homes\Hayden-4EHB.rup Calc=MJS House faces:SW <br />
The URL can be used to link to this page
Your browser does not support the video tag.