Laserfiche WebLink
, 1, <br /> FC7RM R405-2014 - ._ <br /> FLt�R1DA ENERGY EF�ICIENCY CODE-Ft3R BUIC.DING GONSTRUCTtON <br /> - - - Florida Department of Business and Prafessional Regulation-- Residential Pertormance Method <br /> - � <br /> Project Name: Galen Elevation L} Builder Name: DRN�pr�ss�es <br /> Street: (,���(E,����`� ���-p�;��C � Permit C7ffice: C,{`�y �rY `«S <br /> Gity,Staie,Zip: Zephyrhills,FL,-7 2�� �„/ 4� Permit Number: f�12-s� <br /> dwner: `�`� <br /> . C�,�� Jurisdiction: G�l�{o� <br /> Design Location: FL,Tampa County:: Pasco(Florida Glimate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area <br /> 2. Single family or rriultiple family Sit�g(e-family a.Frame-Wt�od,Exterior R=11.d f 269.3Q ft2 <br /> b.Goncrete Block-Int(nsut,Exterior R=4 1 956.22 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Waod,Adjacent R=11.0 286.00 ftz <br /> 4. Number af Bedroarras 4 d��fA R= fi2 <br /> 10.Cei(ing Types (1451.0 sqft.) Insulation Area <br /> 5. Is this a worst case? _ No. a.Under Attic(Vented) R=30.0 1451.00 ft� <br /> 6. Gonditioned floor area above grade{ft2} 2432 b.NtA Ft- ft2 <br /> Conditioned floor area below grade(ft�) 0 c.N/A R= ft� <br /> 11.Ducts R ftz <br /> 7. Windows(229A sqft.} Descriptian Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floar 6 231 <br /> a. U-Factor: Dbl,U=0.34 189.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.5b 4o.aa ft2 12.Cooling systerns kBtuthr Efficienoy <br /> SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 <br /> c. U-Factar N!A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft� a.Electric Heat Pump 33.8 HSPF:8.20 <br /> SHCaG: ' <br /> Area Weighted Average Overhang Depth: 1.585 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Fioor Types (145i.0 sqft.} insulation Area a.Electric Gap:50 ga(ions <br /> a.Slab-On-Grade Ed e Insulation R=0.0 1019.00 ft2 EF:0.950 <br /> 9 6. Conservation features <br /> b.Floor over Garage R=t 9A 432A0 ft� None <br /> c.N/A R= ft� 15.Credits Pstat <br /> Total Prapased Modified Loads: 73.95 �y A�� <br /> Glass/Floor Area: 0.094 rM <br /> 7otal Baseline Loads: 74.48 <br /> I hereby certify tnat the plans and specifications covered by Review of the plans and �.��k1E ST.q�,� <br /> this caiculation are in camp(iance with the Florida Energy ' specificatians covered by this ,�a � _ � p� <br /> % z�w.~ <br /> Cade. calculation indicates compliance �+`�,,, - ��o .,�n <br /> with the Florida Ener Cade. �• �rrrr�'{;: '=`�:�°';;�='." c` <br /> 9Y � r} R�..�-.� .. « O <br /> PREPARED BY: �'►�k.�•�•� Before construction is completed :'' .."� '�,. � <br /> DATE: io-3o-n this buildin will be ins ected for �'�`" d <br /> 9 P t? �"�;�-: � ,� <br /> comp(iance with Section 553.508 * �� <br /> r � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ,�, �,S <br /> with the Flarida Energy Code. �'t3gj��� <br /> OWNER/AGENT: �%'" ' ��>�� BUILDING OFFICIAL: <br /> DATE. �� 1���-' �Ar�: - <br /> - Compliance requires certification by fhe air handier unit manufacturer#hat the alr handter enclosure qualifies as <br /> ( certified factory-seated in accordance with R403.2.2.1. <br /> � -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> ' test report in accordance wiih R4Q2.4.1.2. <br /> - Compliance with a proposed duct leakage Gtn requires a Duct Ceakage Test Repart confirming duct leakage to outdoors, <br /> i tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whale house. <br /> ( <br /> 1 0/30/201 7 4:19 PM EnergyGauge�U�A-FlaRes2014 Sectian R405.4.1 Compliant Software Page 1 of 5 <br />