My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19235
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19235
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:17:55 AM
Creation date
9/21/2018 9:17:52 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19235
Building Department - Name
DR HORTON INC
Address
6767 EZRA LOFT PLACE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOFtM R405;2014 ' <br /> � ' Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance and Prescri tive Methods <br /> ADDRESS: Permit Number: - , w_ <br /> Zephyrhills,F�, - , <br /> MANCIATORY REQUIREMENTS See individual code sectio�s'for full details. <br /> � 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) <br /> display card be campleted and certified by the builder to be accurate and correct before fina!approval of the building for occupancy.Florida law <br /> [Section 553.9085,Fla�ida Statues]requires the EPC display card to be included as an addendum to each sa(es contract for both presold and <br /> nanpresold residential buildings.The EPL display card contains infarmation indicating the energy pertormance level and efficiencies of components <br /> installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by tne builder accurately reflects the plans <br /> and specifications submitted ta demonstrate campliance for the building.A capy of the EPl..dsplay card can be€aund in Appendix C <br /> � R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of <br /> Sections R402.1 thro�gh R402.4.4. <br /> Q R402.4.1 Buiiding thermal envelope. The building thermal envelope shall comply with Sections R402,4 1.1 and R402.4 1.2.The <br /> sealing methods between dissimilar materials shall al(ow for differentia!expansion and cantraction. <br /> • R402.4.1.1 installation. The components af the building thermal envelope as listed in Table R402.4 1.1 shall be installed in <br /> accordance with the manufacturer's instructions and the criteria listed in Tahle 402.4,1 1,as applioable to the method of construction. <br /> Where required by ihe cade afficial,an approved fhird party shall inspect a!1 camponents and verit�t compliance. <br /> • R402.4.1.2 7esting. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air <br /> chatages per hour in Giimate Zonas 1 and 2,and 3 air changes per hour in C(imate Zones 3 through 8.Tesfing shal(be conducted with <br /> a blower door at a pressure of 0.2 inches w.g.(50 Pascals}.Where required by the code official,testing shall be cpnducted by an <br /> approved third party.A written report of the results of the test shall be signed by the party conducting the test and pravided to the code <br /> official.Testing shall be performed at any Time after creation of a11 psnetrations of the building thermal envelope. <br /> During testing: <br /> 1.EMerior windows and daors,fireplace and stove doors shall be closed,but noi sealed,beyo�d ihe intended weatherstripping or <br /> other infi(tratian oontrol measures; <br /> 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended <br /> infiltration ca�trol measures; <br /> 3.Interior doors,if insta(Ied at the time af the fest,shall be open; <br /> 4,Exterior doors for continuous ventilation systems and heat recovery ventilators shail be closed and sealed; <br /> 5.Heating and cooling systems,if insialled af Yhe time of the tesi,sha!!be turaed off;and <br /> 8,Supply and return registers,if instal(ed at the tirne of the test,shal(be ful(y open. <br /> O R402.4,2 Fireplaces. New wood-buming fireplaces shall have tight-fitting flue dampers and outdaor combustion air, <br /> O R402.A.3 Fenestration air teakage.Windows,skylights and sliding glass doors shall have an air infiltratinn rate of no more than 0.3 cfm <br /> per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or <br /> AAMA/WOMA/CSA 141tI.S.21A440 by an accredited,independent lat�ora#ory and listed and labeled by the manufacturer. <br /> Exception: Site-built windows,skylights and doars. <br /> O R402.4.4 Recessed lighttng. Recessed luminaires instailed in the building thermal e�velope shall be sealed to limit air leakage <br /> between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not <br /> more than 2.0 cfm(0.944 lJs)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.Al!recessec! <br /> lumi�aires sha11 be sealed with a gaskef or cau[k befween the hausing and the interiar wal(or ceiling cavering. <br /> � R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. _ <br /> � R903.1.3 Heat gump supplerr�entaty heat(Mandatory}. !-3eat pumps having supplsmenfary e(ectric-resistance heat shai(have controls <br /> that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ' <br /> � R443.2.2 SealEng{Mandatary)A!!ducts,air hand(ers,and filter boxes and building cavities thai form the primary air canfainment <br /> passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance <br /> with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construc#ion <br /> or rough-in tesiing below. <br /> Duct tightness shall be verified by testing to u�ection 803 of the RESNET Standards by either an energy rater certified in accordance with Section <br /> 553.99,Florida Statutes,or as autharized by Flaida Statutes,to be"substaniially leak free"by either of the fo!lowing: <br /> 1. Post-construction test:Tota�leakage shail be less than or equal to 4 cfm (113 Umin)per 100 square feet(9.29 m2)of conditioned floor area <br /> when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Ali . <br /> register boots shall be teped ar otherwise sealed during the tesi. <br /> 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm (113 Umin)p�r 100 square feet(9.29 m2)of oonditioned floor area when tested <br /> at a pressure differentiai af 0.1 inches w.g.(25Pa)across the sysierrt,inc(uding the manufac#urer's air handler enclosure.AII registers shall be <br /> taped or otherwise sealed during the test.If the air fiand(er is not installed at the iime ofi the test,total leakage shall be less than or equal to 3 cfm <br /> (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. <br /> Exceptians: <br /> 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. <br /> 2. Duct testing is not mandatory for buildings camplying by Sectian R405 of this cade. <br /> 10J90t2017 4:19 PM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Gom Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.