Laserfiche WebLink
, , - <br /> FLC}RIDA E�UERGY �FFI�I�NCY' CODE <br /> FOR �UtLDING CONSTRUCTION - w <br /> Enveiope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: Galen E}evation D _ Builder Name: QRH Express Nomes <br /> Street: Permit O�oe: <br /> City,State,Zip: Zephyrhills, FL, Permit Number: <br /> Design Location: F�,Tampa Jurisdictian: � <br /> Cond.Floor Area:: 2432 sq.ft. Gond.Volume: 20139 cu ft. <br /> � <br /> � <br /> Envelope Leakage Test Results Leakage Characteristics <br /> Regressian Data: <br /> C: n: R. <br /> . CFM{50): <br /> Single or Multi Point Test Data <br /> HOUSE PRESSURE F�pt11/; ELA: <br /> 1 Pa cfm EqLA: <br /> 2 Pa cfm ACH: <br /> 3 Pa cfm <br /> ACH(50}: <br /> 4 Pa cfm <br /> 5 Pa cfm S�� <br /> 6 Pa cfm <br /> R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour <br /> in Giimate Zones 1 and 2,3 air changes per hour in Ciirrtate Zanes 3 through 8.Testing shall be canducfed with a b(ower doar at a p�essure of 02 <br /> inches w.g.{50 Pascals}.Where required by the code officiai,testing sha(I be conducted by an approved third party.A written report of the results of the <br /> test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrafions of tt�e buiiding thermai envelope. <br /> During testing: <br /> i.E�cterior windows and doors,fireplace and stove doars sha!!be closed,but not sealed,beyand the intended weaiherstripping or ather <br /> infiltratian control measures; � <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration <br /> control measures; <br /> 3.lnterior doars,if installed at the time of the#est,shali be apen; <br /> 4.Exterior doors for co�tinuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooiing systems,if installed at the time of tfie test,sfial(be turned off;and <br /> 6.Supply and retum registers,if installed at the time of the test,shall be fuily open. <br /> I hereby certify tha#the above envelope leakage W here required by the code offieial, ' ��"���x�4�� <br /> performance results demonstrate comp(iance ' testing shal(be canducted by an �,'� ,,, 's . �. �,�„ <br /> with Florida Energy Code requirements in approved third party.A written � '���� ti ,,:.�,.-',.��;,. "� <br /> accordance with Section R402.4.1.2. report of the results of the test shall �" �""� `"' '"f�"�`�`y' � <br /> be signed by the third party � . -.�,���� ..�:4`,..�`* � � <br /> conducting the test and pravided to � � �, .� <br /> SIGNATtJRE: the code officia(. <br /> PRIN1'ED NAME: f��������� <br /> BUll,D1NG QFFlCtAL: <br /> DATE; DATE: <br /> 1 0/30/201 7 4:20 PM EnergyGauge�USA-FlaFies2014 -Sectian R405,4.1 Compliant Software Page 1 of 1 <br />