� 4 . <br /> � Pro ect Summar �Ob' <br /> -�1- �reghtsof� Entire House y Byte: o�t o�,zo,4 <br /> Progressive Air. Systems, Inc <br /> 5907 Dasher Ct,PoR Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' � • <br /> For: DR Horton/Exp ress <br /> Lot 46 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> � - o • � <br /> Weather: Tampa Intl AP, FL, US .. <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 °F Outside db gi °F <br /> Inside db 70 °F Inside db 75 �F <br /> Design TD 30 °F Design TD 16 °F <br /> Daily range � <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 18093 Btuh Structure 18565 Btuh <br /> Ducts - 4796 Btuh Ducts 5812 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower e� 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 22889 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> ' InflltratiOn Equipment sensible load 24377 Btuh <br /> Method simplitied Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2371 Btuh <br /> - Ducts 880 Btuh <br /> Central vent (0 cfm) - 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz 2478 2478 Equipment latent load 3250 Btuh <br /> Volume�ft3) 20539 20539 <br /> Air changes/hour 0.22 0.11 Equipment total load 27628 Btuh <br /> Equiv.AVF (cfm) 75 38 Req.total capacity at 0.75 SHR 2.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary � <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> M ��** <br /> odel CH14NB036 A **** <br /> AHRI ref <br /> Cond CH14NB036 A <br />, Coil FB4CNP036 <br /> AHRI ref <br /> . Efficiency 8 HSPF Efficiency 11.7 EER, 14 SEER <br /> , Heating input Sensible cooling 25200 Btuh <br /> Heating output 34000 Btuh� 47°F Latent cooling 8400 Btuh <br />�, Temperature nse 28 °F Total cooling 33600 Btuh <br />� Actual air flow 1120 cfm Actual air flow 1120 cfm . <br /> - Air flow factor 0.049 cfm/Btuh Air flow factor 0.046 cfm/Btuh <br />', Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=30°F <br /> Backup: <br /> input=8 kW, Output=25681 Btuh, 100 AFUE ' <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .�. -�- wrightsoftm 2017-Oct-30 1621:38 <br /> �-- Right-Suite�Universal 2017 17.0.21 RSU25554 Pa <br /> �� ..les\Express homes\Galen 4EG8-3 ton New Code.rup Calc=MJB House taces:NE _ 9e� <br />