Laserfiche WebLink
� FLORIDA ENERGY EFFICIENCY CODE <br /> - � - FOR BUILDING CONSTI�UCTION� - <br /> Envelope Leakage Test Report <br /> - Prescriptive and Performance Method � <br /> Project Name: Hayden 4EH6 Elev C Builder Name: DRH Express Homes <br /> Street: Permit Office: <br /> City,State,Zip: Zephyrhills,FL, Permit Number: <br /> Design Location: FL,Tampa Jurisdiction: <br /> Cond.Floor Area:: 2608 sq.ft. Cond.Volume: 21580 cu ft. <br /> Envelope Leakage Test Results Leakage Characteristics <br /> Regression Data: <br /> C: n: R: <br /> CFM(50): <br /> Single or Multi Point Test Data <br /> HOUSE PRESSURE FLOW: E�' <br /> 1 Pa cfm EqLA: <br /> 2 Pa cfm ACH: <br /> - 3 Pa cfm <br /> ACH(50): <br /> 4 Pa cfm <br /> 5 Pa cfm S�� <br /> 6 Pa cfm <br /> R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour <br /> in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 <br /> inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the <br /> test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> infiltration control measures; - <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration <br /> control measures; <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> � 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and <br /> 6.Supply and return registers,if installed at.the time of the test,shall be fully open. <br /> I hereby certify that the above envelope leakage W here required by the code official, ' 0�'���x•��� <br /> performance results demonstrate compliance testing shall be conducted by an �.`+� ,,; =;; �,�, <br /> with Florida Energy Code requirements in approved third party.A written � ;��r -r =_� �a,``"� <br /> a c c o r d a n c e w i t h S e c t i o n R 4 0 2.4.1.2. r e p o rt o f t h e r e s u l t s o f t h e t e s t s h a l l � rr"1`�4`",':°?:"'s`�:'` �' o <br /> r� '_`;._ � : <br />, be signed by the third party � .:.__:��_._ .._ r1 <br />�� conducting the test and provided to � ����;.Q �` <br /> SIGNATURE: tfie code official. <br /> PRINTE <br /> D NAME: . ��������� <br /> BUILDING OFFICIAL: <br /> DATE: DATE: � <br /> 10/30/2017 1:43 PM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 <br />