My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19237
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19237
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:20:42 AM
Creation date
9/21/2018 9:20:40 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19237
Building Department - Name
DR HORTON INC
Address
6679 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; . <br /> FORM R405-2014 � � <br /> FL'ORIDA ENEF�GY EFFiCIENCY CODE �OR �UILDIf�11G CONST�UC�@O� <br /> _ _. Florida Department of Business and Professional Regulation r�Residential Performance Method <br /> Project Name: Elle Elevation D Builder Name: DRH Express Homes <br /> Street: �(,1 ����CC���^�i�`S� � Permit Office: <br /> City,State,Zip: Zep�iyr ills,FL,.�,11���,`7 �z' � Permit Number: <br /> - Owner: .1.1�{I r 10 � Jurisdiction: -, <br /> Design Locationc FL,Tampa ���' County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) . 9. Wall Types(2595.2 sqft:) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1253.30 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1084.80 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 257.11 ftz� <br /> 4. Number of Bedraoms 5 d.N/A R= ftZ <br /> 10.Ceiling Types (1550.0 sqft.) insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1550.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2823 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A - R= ftz <br /> 11. Ducts R ft2 <br /> 7. Windows(267.5 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 265 <br /> a. U-Factor: Dbl, U=0.34 227.50 ftz . _ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A . ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overtiang Depth: 1 626 ft. <br /> Area Weighted Average SHGC: 0.314 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1550.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1330.00 ftz b. Conservation features <br /> b.Floor over Garage R=19.0 220.00 ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 81.50 n��� <br /> Glass/Floor Area: 0.095 Total Baseline Loads: 81.97 r <br /> f hereby certify that the plans and specif�cations covered by Review of the plans and �.����T,�?,fi <br /> this calculation are in compliance with the Florida Energy specifications covered by this -� =� p <br /> Code. calculation indicates compliance ��',;,°'!�� '_::`,,.� �ws+ <br /> ;.,�,� .�� t` <br /> with the Florida Energy Code. ti �r,;,�„<<.' y f .���„ o� <br /> PREPARED BY: 1.'N1c_tQ..••.:•� Before construction is completed ' " - " ..� <br /> �- � �s�_�,--,� . C7 <br /> DATE: ►o-�-�� this building will be inspected for � �-�- ,�, <br /> compliarice with Section 553.908 * ��'�.° , � <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. ,� �,S <br /> with the Florida Energy Code. �'f3rj��� <br /> OWNER/AGENT:/'J������/'�J1 BUILDING OFFICIAL: <br /> DATE: ll/1.� � I ` DATE: �/��_:! <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as_ <br /> certifi�d factory-sealed in accordance with R403.2.2.1. . � � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> -test report in accordance with R402.4.1.2. <br /> 10/30/2017 1:17 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.