Laserfiche WebLink
Manual S Compliance Report JOb' <br /> �" WCIC„�ritSC1�� Date: Oct 10,2014 <br /> Enfire House - �y: <br /> Progressive Air Systems, lnc <br /> 5907 Dasher Ct,Port Richay,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CACd33669 <br /> � • ' • • <br /> Far: DR HortoN�xpress Homes <br /> Lot 44 B!k 6 Silverada Raizch, Zephyrhills, F�. <br /> . � • • • <br /> Design Conditions ' <br /> Outdoar design DB: 912°F Sensible gain: 30895 Btuh � Entering cail DB: 76.5°F <br /> Outdoor design WB: 77.1°F Latent gain: 4350 Btuh Entering coil WB: 63.2°F <br /> � lndoor design DB: 75.d°F Total gain: 35245 Btuh <br /> Indaar RN: �50°la Estimated airfiow: 1367 cfm <br /> Manufacturer's Pertormance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Carrier Model: CH14NB042`*"`*A+FB4CNP042L <br /> Actual airfiow: 1367 cfm <br /> Sensibie capacity; 32368 Btuh 105%of(oad <br /> Latent capacity: 6369 Btuh 146°/4 of load <br /> Tatal capacity: 38737 Btuh 110°lo af load SHR: 84°l� <br /> • i t <br /> Design Conditions. - <br /> ' Outdoor design DB: 40.0°F Heat lass: 26626 Btuh Entering coil DB: 69.4°F <br /> Indoor design DB: 70.0°F - <br /> 1 <br /> Manufacturer's Performance Data at Actua! Desrgn Gonditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier = Model: CH14NB042****A+F'84CNP042L. <br /> Actual airflow: 1367 efm <br /> Output capacity: 37278 Btuh 140%of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Ecanamic balance: -99 °F <br /> , Backup equipment type: E1ec strip <br /> � Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 8.6 kW 110%of load Temp. rise: 18 °F <br /> � - Meets are ail requirements of ACCA Manual S. <br /> i <br /> .t wt'1 htsoft� 2on-oct-so�s:zy:ss <br /> ,,.,�, g Right-Suite�Universal 2017 17.021 RSU25554 Page i <br /> � ...eslE�ress hameslE[Ie 4EJB-3.5 ton New Code.rup Catc=MJ8 House faces:SE <br /> i <br /> I <br />