Laserfiche WebLink
-� <br /> 9 � Pro ect Summar JOb' <br /> � wri .htsoft Entire House y Byte: o�t,a,zo,a <br /> Progressive Air Systems, Inc � <br /> 5907 Dasher Ct,PoR Richey,FL 34668�Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 . <br /> � � ' • • <br /> For: DR Horton/Express Homes <br /> Lot 40 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> � - • • � <br /> Weather: Tampa Intl AP, FL, US � <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 °F Outside db 91 °F <br /> Inside db 70 °F - - 1nsi�e db 75 °F <br /> Design TD 30 °F Design TD 1 g �F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 19683 Btuh Structure 21509 Btuh <br /> Ducts 6943 Btuh Ducts 9386 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower , 0 Btuh � <br /> Piping 0 Btuh <br /> Equipment load 26626 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Inflltl'atlon Equipment sensible load 30895 Btuh <br /> Method SimPlified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2781 Btuh <br /> Ducts 1569 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz 2845 2845 Equipment latent load 4350 Btuh . <br /> Volume�ft3) 23685 23685 <br /> Air changes/hour 0.22 0.11 Equipment total load 35245 Btuh <br /> Equiv.AVF (cfm) 87 43 Req. total capacity at 0.75 SHR 3.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br />, Trade CARRIER <br /> Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB **** � <br /> AHRI r 042 A <br />, ef Coil FB4CNP042L <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 30000 Btuh <br /> Heating output 41000 Btuh� 47°F Latent cooling 10000 Btuh <br />' Temperature rise 27 °F Total cooling 40000- Btuh <br />� Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.051 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br />' Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Cap�city balance point=31 °F � <br /> Backup:. <br /> ' Input=9 kW, Output=29290 Btuh, 100 AFUE � <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. li <br /> .� '-�- wrightsoftm 2on-oct-so is:2l:ss <br /> �� Right-Suite�Universal 2017 17.0.21 RSU25554 Pa9e� <br /> ...es\Express homes\Elle 4EJB-3.5 ton New Code.rup Calc=MJ8 House faces:SE <br />