My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19239
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19239
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:22:22 AM
Creation date
9/21/2018 9:22:20 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19239
Building Department - Name
DR HORTON INC
Address
6694 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � <br /> Pro ecfi Summar �°b: <br /> -��f- wrightsoft� Enti e House y �yte: o�t,o,zo,a <br /> Progressive Air Systems, (nc <br /> 5907 Dasher Ct,Port Richey,F134668 Phone:727-847-3898 F�:727-$t5-3999 license:GAC033669 <br /> � • ' • i <br /> For: DR HortoNExpress <br /> Lat 3 Bfk 6 Silverada Ranch, Zephyrhills, F!. <br /> Rlotes: . <br /> . p - • � � <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Canditions Summer Design Canditions <br /> Outside db 40 �F Outside db 91 °F <br /> lnside db 70 °F Inside db 75 °F <br /> Design TD 30 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Caoling Equipment Load Sizirtg <br /> Structure 17539 Btuh Structure 16295 Btuh <br /> Qucts 356'! Btuh Qucts q598 Btuh <br /> Central vent (d cfm} 0 8tuh Central vent (0 cfm} 0 Btuh <br /> (none) (none) <br /> Humidification Q Btuh Ei(awer _ 0 gtuh <br /> Piping 0 8tuh - <br /> Equipment load 2110Q Btuh Use manufacturer's data y <br /> � Ratelswing multiplier 1.OQ <br /> Infittration Equipment sensible load 20893 Btuh <br /> Method s;mplified Latent Cooling Equipment Load �izing <br /> Ganstructian quality Serr7�-tight <br /> Fireplaces 0 Structure 2360 Btuh <br /> Ducts 606 Btuh <br /> Cer�tral vent{0 cfm} 0 B#uh <br /> Heating Cooling (none) <br /> Area(ft2 1820 1820 Equipment la#ent load 2966 Btuh <br /> Volume�ft3} 16012 16012 <br /> Air changes/hour 0.26 0.14 Equipment total load 23859 Btuh <br /> Equiv.AVF (cfm) 69 37 Req. tatal capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Coaiing Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRlER � Trade CARRIER <br /> Model CH14NB030*'`"``A Cond CH14NB03.0****A <br /> AHR! ref Goi! F'B4CNF030 <br /> AHRI ref ' <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Neating output 29600 Btuh @ 47°F E..atent coal9ng 7500 8tuh <br /> Temperature rise 27 °F Tatal coaling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 100Q cfm <br /> Air flow factar 0.047 cfmtBtuh Air flow factor 0.048 cfmlBtuh <br /> Static pressure Q in H20 Static pressure 0 in H20 <br /> Space thermastat Load sensible heat ratio 0.88 <br /> Capacity balance point=32°F <br /> Bac4cup: <br /> Input=7 kW, Output=22477 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ��"�"wrightsoft' Right-Suite�Universal 2017 17.0.21 RSU25554 2017-0ot-3�i3:02:43 <br /> Page 1 <br /> ...on\Wrightsoft Files\E�ress homeslCali 4EBB.rup Calc=MJ8 House faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.