t i <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes <br /> street: 3123 Moulden Hollow Drive Permit offce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ft� 1936 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11.Ducts R ftz <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rtn,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (1936.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ' _O�T�:ST��,�_-.< <br /> this calculation are in compliance with the Florida Energy specifications covered by this ` .,y ,�. ' __.-�� 0�,. <br /> Code. calculation indicates compliance �3�r,,,''' `;'',:�� �.�c+ <br /> ,. �a�,a :C` <br /> /I with the Florida Energy Code. `ti'- ri�rr�%"��°���.;,,;�� � <br /> PREPARED BY: �G�'V� f��l'IGVc Before construction is completed � - '`�y �`'� �'�` �. <br /> DATE. this building will be inspected for � _���`��- �� � <br /> compliance with Section 553.908 '�* -� � ; * <br /> I.hereb certi that this buildin as desi ned,is in com liance Florida Statutes. �- <br /> Y fY 9� 9 P �= = - <br /> with the Florida Energy Code. C017 y�'t'�'�- <br /> OWNER/AGENT: BUILDING OFFICIAL: � <br /> DATE. DATE: - �' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 1:21 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />