Laserfiche WebLink
< < , , . <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE F.O;R BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575A sf ADS 2017 Builder Name: Lennar Homes <br /> street: 3111 Moulden Hollow Drive Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner. �ennar Homes .lurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Singie family or multiple family Singie-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz <br /> b.Concrete Block-Int Insul,E�erior R=4.1 996.67 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ <br /> 4. Number of Bedrooms 4 d.N/A R_ ftz <br /> 5. Is this a worst case? Yes <br /> 10.Ceiling Types (1491.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1491.00 ft= <br /> 6. Conditioned floor area above grade(ftZ) 2584 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11.Ducts R f�= <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic, Ret:2nd Fioor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ft� b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ftZ 12•Cooling systems kBtulhr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor. Dbl,U=0.56 33.33 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2584.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features <br /> b.Fioor Over Other Space R=0.0 1051.00 ftZ None <br /> c.other(see details) R= 440.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.068 <br /> Total Proposed Modified Loads: 74.43 pASS <br /> Total Baseline Loads: 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and TI�E:S� �' .,, <br /> o��_ �T <br /> this calculation are in compliance with the Florida Energy specifications covered,by this ' .f "=�a --p <br /> �i�;� i:4��: r{+. '; <br /> Code. calculation indicates compliance ` � �,,,� = a��.�.�,rc+ :, <br /> �ave �l�l�rcl� with the Florida Energy Code. [•. rr��,�`%%;�';=�;°;,���'ti��O <br /> PREPARED BY: Before construction is completed r i � ""` ," �. <br /> DATE: this building will be inspected for � ����� - = .� <br /> compliance with Section 553.908 * -���� � -�, ` <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �",� <br /> with the Florida Energy Code. �G'Op ��� <br /> 1NE:.. <br /> OWNER/AGENT� BUILDING OFFICIAL: <br /> DATE. DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house. <br /> 7/6/2017 6:48 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />