Laserfiche WebLink
� � , <br /> FORM R405-2014 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br />� 1 Wholehouse Proposed ACH(50) .000367 2488.2 136.6 256.9 .339 7 <br />,I HEATING SYSTEM I <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.5 17.5 kBtu/hr 1 sys#1 <br /> 2 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 2 sys#2 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER: 16 18 kBtu/hr 540 cfm 0.85 1 sys#1 <br /> 2 Central Unit � Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 <br /> � HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> � 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None <br />� SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ftz <br /> DUCTS <br /> / —Supply— —Return— Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 Attic 6 218.6 ft 2nd Floor 54.6 ftZ Proposed Qn 2nd Floor —cfm 76.5 cfm 0.07 0.60 1 1 <br /> I 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 104 4 cfm 0.07 0.60 2 2 <br /> TEMPERATURES <br />' Programable Thermostat:Y Ceiling Fans: <br /> Coolin Jan [ ]Feb [ ]Mar [ ]A r [ ]Ma X]Jun X]Jul [X]Au X]Se [ ]Oct [ ]Nov [ ]Dec <br />' Heating Jan [X]Feb [X]Mar [ ]Apr [ ]May 4 ]Jun 4 ]Jul [ ]Au9 4 ]SeP [ ]Oct [X]Nov [X]Dec <br /> II Ventin Jan [ ]Feb [X]Mar [X]A r [ ]Ma [ ]Jun [ ]Jul [ ]Au [ ]Se [X�Oct [X]Nov [ ]Dec <br /> I <br /> 7/6/2017 6:48 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 <br />