Laserfiche WebLink
Pro ect Summa Job: 2575A1 sf ADS 2017 <br /> J � Date: 1013012017 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - � • <br /> For� Lennar Homes <br /> N otes: <br /> ■ - • � • <br /> Weather: Tampa InternationalAP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br />' Outside db 31 °F Outside db 91 °F <br />� Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Siaing <br /> Structure 11004 Btuh Structure 17080 Btuh <br /> Ducts 1846 Btuh Ducts 2137 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12850 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Inflltl'atlon Equipment sensible load 19217 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2266 Btuh <br /> Ducts 379 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heatin Cooling (none) <br /> Area(ft2 149� 1491 Equipment latent load 2645 Btuh <br /> Volume�ft3) 11928 11928 <br /> Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21862 Btuh <br /> Equiv.AVF (cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make � Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024230-21 Cond 14HPX-024-230-21 <br /> AHRI ref 10258598 Coil CBA27UHE-024230*++TDR <br /> AHRI ref 10258598 <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.062 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point= 17°F <br /> Backup: <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> L -�- wrightsoftm 2017-Oct-30 08:17:05 <br /> �� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...BA27UHE AH's\2575A sf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces: E <br />