Laserfiche WebLink
� • t P . . <br /> Manual S Compliance Report Job: 2575A1 sf ADS 2017 <br /> Date: 10130/2017 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - • • <br /> For� Lennar Homes <br /> • � • • • <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 19217 Btuh Entering coil DB� 75.6°F <br /> Outdoor design WB. 77.3°F Latent gain: 2645 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21862 Btuh <br /> Indoor RH: 50% Estimated airflow� 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer Lennox Model: 14HPX-024230-21+CBA27UHE-024-230`'++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 111% of load <br /> Latent capacity: 3780 Btuh 143% of load <br /> Total capacity: 25200 Btuh 115% of load SHR: 85% <br /> • . • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss 12850 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 170% of load Capacity balance: 17 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer Model: <br /> Actual airflow� 800 cfm <br /> Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. , <br /> zon-oct-sa oa:n:os <br /> �� � wrightsoft° Right-Suite�Universal 2017 17.0.23 RSU05714 <br /> �� Page 2 <br /> ...BA27UHE AH's\2575A sf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces: E <br />