My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19244
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:37:13 AM
Creation date
9/21/2018 9:37:11 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19244
Building Department - Name
LENNAR HOMES LLC
Address
3221 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summa1�� Job: 1941A sf ADS <br /> 1 ',7 Date: 8/1412017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' � - • � <br /> For: Lennar Homes <br /> Notes: 2017 <br /> � - • • • <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 25666 Btuh Structure 22903 Btuh <br /> Ducts 3223 Btuh Ducts 3621 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 28888 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 26524 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 3625 Btuh <br /> , Ducts 646 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2 1936 1936 Equipment latent load 4271 Btuh <br /> . Volume�ft') 16360 16360 <br /> Air changes/hour 0.34 0.18 � Equipment Total Load (Sen+Lat) 30795 Btuh <br /> Equiv.AVF (cfm) 93 49 Req. total capacity at 0.85 SHR 2.6 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-036-230-21 Cond 14HPX-036-230-21 <br /> AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR <br /> AHRI ref 10258589 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 29580 Btuh �� <br /> Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh , <br /> Temperature rise 25 °F Total cooling 34800 Btuh <br /> Actual air flow 1200 cfm Actual air flow. 1200 cfm <br /> Air flow factor 0.042 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> , Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.86 <br /> Capacity balance point=29°F <br /> � Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ���+ wrightsoftm 2017-Aug-14 1039:51 <br /> Right-SuiteQ�l Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJS Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.