My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19245
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19245
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:38:50 AM
Creation date
9/21/2018 9:38:48 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19245
Building Department - Name
LENNAR HOMES LLC
Address
3130 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i_ ., . <br /> Y-;�_� <br /> FOR'UI R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE;FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regufation - Residential Performance Method <br /> Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes 0111 <br /> street: 3130 Moulden Hollow Drive Permit Office: Cl of�e�l.yrhills <br /> City,State,Zip: ,FL, Permit Number j�Z�f�S ' <br /> Owner. Lennar Homes Jurisdiction: 61I OO <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz <br /> 4. Number of Bedrooms 4 d•N�p` R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1489.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R ftZ <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 71.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br />, SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features <br />' b.Floor Over Other Space R=0.0 1049.00 RZ None <br /> c.other(see details) R= 440.00 ftZ �5.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.47 pASS <br /> Total Baseline Loads: 74.41 <br />'� I hereby certify that the plans and specifications covered by Review of the plans and ��T�ST,��.� .� <br /> this calculation are in compliance with the Florida�Energy specifications covered by this b' , ' �_�. O . <br /> f, .__,=��� <br /> Code. calculation indicates compliance ���;,,'�� -- �,,.�`��+ � <br /> C_ � <br /> /" with the Florida Energy Code. F+� jrrrr��"%�•:�r-�:��;;>;�,_ � , <br /> PREPARED BY: '�aVe f��{'jGYc Before construction is completed � �:�� '" " o <br /> DATE: this building will be inspected for � -`�;,;� �- �' �. <br /> compliance with Section 553.908 # ''.`'��'�' :- �, <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � �. <br /> with the Florida Energy Code. �''Orj y���.�` <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air han ler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403. .2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br />� tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br />' 8/14/2o17 11.35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> II� <br />� � , <br />
The URL can be used to link to this page
Your browser does not support the video tag.