Laserfiche WebLink
Y � • <br /> FORAII R405=2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes <br /> 0111 <br /> street: 3130 Moulden Hollow Drive Permit ot�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner Lennar Homes JUrisdiction: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft� <br /> b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 10.Ceiling Types (1489.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ftZ <br /> 6. Conditioned floor area above grade(ft� 2582 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11.Ducts R ft2 <br /> 7 Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71,25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr E�ciency <br />� d. U-Factor: N/A ftz a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1 190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br />` EF�0.950 <br />� a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features <br />� b.Floor Over Other Space R=0.0. 1049.00 ftz None <br /> c.other(see details) R= 440.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.47 � A C C <br /> � Total Baseline Loads: 74.41 f1���� <br /> I hereby certify that the plans and specifications covered by Review of the plans and i �'��:�T,,��, . <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��d _ � ,�'d�`�., <br /> Code. calculation indicates compliance �'" lj��'4�� '"=,s:��```�,Y, .. <br /> �ave �✓�G� with the Florida Energy Code. •�+ na,r���%•�:`".�''•���ti � <br /> PREPARED BY: �w� Before construction is completed �- <br /> � . Y �, i �'. :."'.�' C <br /> DATE: this building will be inspected for � �'I�,��, _ �. <br /> compliance with Section 553.908 ' �.. -�� ° , .�., <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. .�;- <br /> Y fY 9� 9 P '� �.. , <br /> with the Florida Energy Code. �OZj'yq�.T��� <br /> OWNER/AGENT. BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house. <br /> 8/14/2017 11:35 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />