Laserfiche WebLink
Pro ect Summa Job: 2575B sf ADS <br />, � � Date: 10130I2017 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • • <br /> For: Lennar Homes <br /> Notes: <br /> � - • • � <br /> Weather: Tampa International AP, FL, US I�I <br /> Winter Design Conditions Summer Design Conditions , <br /> Outside db 31 °F Outside db g1 °F I! <br /> Inside db 70 °F Inside db 75 °F � <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 14883 Btuh Structure 10605 Btuh I <br /> Ducts 1400 Btuh Ducts 1655 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) ' <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 16284 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensi6le load 12260 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 942 Btuh <br /> Ducts 294 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1093 1093 Equipment latent load 1237 Btuh <br /> Volume(ft3) 9654 9654 <br /> �Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 13496 Btuh <br /> Equiv.AVF (cfm) 47 25 Req. total capacity at 0.85 SHR 1.2 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-018-230-21 Cond 14HPX-018-230-21 <br /> AHRI ref 10258596 Coil CBA27UHE-018-230*++TDR <br /> AHRI ref 10258596 <br /> Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER <br /> Heating input Sensible cooling 16915 Btuh <br /> Heating output 17100 Btuh @ 47°F ,Latent cooling 2985 Btuh <br /> Temperature rise 26 °F Total cooling 19900 Btuh <br /> Actual air flow 600 cfm Actual air flow 600 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.049 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.91 <br /> Capacity balance point= 31 °F <br /> Backup: <br /> Input=4 kW, Output= 15295 Btuh, 100 AFUE ' <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> c wri htsoftm 2017-Oct-30 06:12:52 <br /> �� g Right-Suite�l Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...A27UHE AH's\2575B sf ADS template 1.52 ton.rup Calc=MJ8 Front Door faces:NW <br />