My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19246
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19246
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:48:30 AM
Creation date
9/21/2018 9:41:42 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19246
Building Department - Name
LENNAR HOMES LLC
Address
3200 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulat�on - Residential Performance Method <br /> Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes <br /> 010 <br /> street: 3200 Moulden Hollow Drive Perri,�t o�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> � Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft: <br /> 4 Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1936.00 ftZ <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftZ <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= " �Z 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.94 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and p��N�.ST,��,� -.� <br /> r :p,` . <br /> this calculation are in compliance with the Florida Energy specifications covered by this � �� ��� , -p� - <br /> Code. ' calculation indicates compliance � �'���,,-''' =_'-�'�.���.�s+. . <br /> • /./ /I with the Florida Energy Code. ��•'�mrr'.�;��%,',;,:�:�'���ti�O . <br /> PREPARED BY. �G�V� �GU1�'IGVI Before construction is completed � i ��• '" ""�:' � <br /> DATE: this building will be inspected for � �y���F , � <br /> compliance with Section 553.908 ' �., -�� � �. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .� _, , �K _ <br /> with the Florida Energy Code. G'Ob'y��� . <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE. DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifles as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.7.2. " <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 1:21 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.