My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19246
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19246
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:48:30 AM
Creation date
9/21/2018 9:41:42 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19246
Building Department - Name
LENNAR HOMES LLC
Address
3200 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Com liance Re ort �ob: 1941BsfADS <br /> p p Date: 10130/2017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • � <br /> For: Lennar Homes <br /> • • • • • <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26017 Btuh Entering coil DB. 75.6°F <br /> Outdoor design WB. 77.3°F Latent gain: 4071 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30088 Btuh <br /> Indoor RH 50% Estimated airflow� 1200 cfm <br /> � <br /> Manufacturer s Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR <br /> Actual airflow� 1200 cfm <br /> Sensible capacity: 29070 Btuh 112% of load <br /> Latent capacity: 5130 Btuh 126% of load <br /> Total capacity' 34200 Btuh 114% of load SHR: 85% ` <br /> . � • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss 28628 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR <br /> Actual airflow� 1200 cfm <br /> Output capacity� 32800 Btuh 115% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br />� Meets are all requirements of ACCA Manual S. , <br /> ,,� wri htsoft' 2017-Oct-30 09:03:17 <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> �'� ...th CBA27UHE AH's\19418 sf ADS template 3ton.rup Calc=MJB Front Door faces: W I <br />
The URL can be used to link to this page
Your browser does not support the video tag.