S ingle F amily,Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots sha11 be graded to comply with�R441.3 af the F.B.C. <br /> 3. Compaction test required if 24" or rnore of fill dirt is brought in at any ane place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. I?riveways require a R.Q.W. use permit. .All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. A11 property markers shall be uncavered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met, <br /> 9. No electric, piumbing, mechanical, or framing shall be cavered withaut an inspection and <br /> appraval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separatian). <br /> 1 l. Appliances shall not be installed in a location where subject to rnechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 af the F.B.C. <br /> 13. Foundation supports for A/C units shail be raised at least 3" abave finished grade. M1308.1 <br /> 14. Return air in all bedraarns. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 af the F.B.G. <br /> 15. All glazing requirements are to be in accordance with R3Q8.4 of the F.B.C. <br /> 17. Ali means af egress are to be in accordance with R311 ofthe F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R'702.4.2 F.B.C. <br /> 19. Combznatian-type AFCI breakers are required at a11 Iocations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new constructian that uses fossil-burning heating <br /> ar appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This zncludes a11 <br /> underground plumbing and electric. <br /> 22. All 20Q8 N.E.C. Cades will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded befare final at least 10 <br /> feet around the structure. <br /> 25.A cop�vf the ener�v cacls shall be with�ermit ut all times <br /> 26. Gopv of final insulation report shall be provided with perniit before�na� <br /> F.F.E.-Finished Floor Elevatian <br /> F.B.C- Florida Building Code 5�'Edition i <br /> R.O.VV.-Right af Way <br /> I A.D.A.-Americans with Disabilities Act N.E.C.-Natianal Electric Code (2008) <br />