My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19248
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19248
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:50:56 AM
Creation date
9/21/2018 9:50:55 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19248
Building Department - Name
LENNAR HOMES LLC
Address
6623 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(. 7 <br /> FORM R405-201�4 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2600A sf ADS Builder Name: LENNAR HOMES <br /> street: 6623 Paden Wheel Street Permit offce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� � y�g <br /> Owner. LENNAR HOMES Jurisdiction: 61160 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family. a.Concrete Block-Int Insul,Exterior R=4.1 2031.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ftZ <br /> 3. Number of units,if multiple family ' 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2599.0 sqft.) Insulation Area z <br /> a.Under Attic(Vented) R=30.0 2599.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2599 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A . R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8 <br /> a. U-Factor. Dbl,U=0.54 141.68 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor; Dbl,U=0.58 72.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 48.00 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: other(see details) 38.50 ft' a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. � <br /> Area Weighted Average SHGC: 0.310 14.Hot water systems <br /> 8. FloorTypes (2599.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft� b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz �5.Credits Pstat <br /> Glass/FloorArea: 0.115 Total Proposed Modified Loads: 81.47 pASS <br /> � Total Baseline Loads: 82.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0�'L�:ST�7,� .< <br /> this calculation are in com liance with the Florida Ener s ecifications covered b tNis r = <br /> P 9Y P Y ,�' �.. � .= =:-�.�_ <br /> Code. calculation indicates compliance .. �'K+r,�, '' _=-�.����.�c+. . <br /> �aVe /w/�C/A with the Florida Energy Code. � ��rrrr�"%%;;;==�"�;;��i�ti,'�O <br /> PREPARED BY: � �/ J� ' """� �y <br /> wl v� Before construction is completed r� " � <br /> #�4 "' ':1�.\!-. _ . r" V, <br /> DATE. this building will be inspected for � ���C�, �: _ <br /> compliance with Section 553.908 *. . �' < =:� � <br /> I hereby certify that this building,as designed, is i compliance Florida Statutes. � :� � <br /> with the Florida Energy Code. ` COD�y�'��__�- <br /> OWNER/AGENT: BUILDING O ICIAL: <br /> DATE: � � DATE: � � <br /> - Compliance requires certification by th air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house. <br /> 9/25/2017 10:45 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.