Laserfiche WebLink
i <br /> Pro ect Summa Job: 2600A sf ADS <br /> J � Date: 912512017 <br /> En fire Ho us e By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' � - � • <br /> For: Lennar Homes _ <br /> , <br /> i <br /> N otes. <br /> � - � • • <br /> - Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing, <br /> Structure 35129 Btuh Structure 28883 Btuh <br /> Ducts 4153 Btuh Ducts 4631 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br />� Piping 0 Btuh <br /> Equipment load 39282 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 33514 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2748 Btuh <br /> Ducts 853 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2599 2599 Equipment latent load 3601 Btuh <br /> Volume(ft3) , 25640 25640 <br /> Air changes/hour 0.22 0.11 � Equipment Total Load (Sen+Lat) 37115 Btuh <br /> Equiv.AVF (cfm) 94 47 Req. total capacity at 0.85 SHR 3.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-042-230-21 Cond 14HPX-042-230-21 <br /> AHRI ref 10258591 Coil CBA27UHE-042-230*++TDR <br /> AHRI ref 10258591 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 36975 Btuh <br /> Heating output 43500 Btuh @ 47°F Latent cooling 6525 Btuh <br /> Temperature rise 28 °F Total cooling 43500 Btuh <br /> Actual air flow 1400 cfm Actual air flow 1400 cfm <br /> Air flow factor 0.036 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure , 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.90 <br /> Capacity balance point= 29°F <br /> Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � <br /> �. -�- wrightsoft' 2017-SeEr25 10:16:21 <br /> �� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...ith CBA27UHE AH's\2600 sfADS drawn 3.5 ton.rup Calc=MJ8 Front Doorfaces: E <br /> � <br />