Laserfiche WebLink
Pro ect Summar�� Job: 2421A sf ADS <br /> J '7 Date: 9/2512017 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New Yark Ave,Hudson <br /> � • ' • � <br /> For: Lennar Homes <br /> Notes: <br /> � - • • • <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 °/a <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 31017 Btuh Structure 24145 Btuh <br /> Ducts 3596 Btuh Ducts 4032 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 34613 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> 111f11t1'atlon Equipment sensible load 28177 Btuh <br /> nnethod Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2700 Btuh <br /> Ducts 732 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2421 2421 Equipment latent load 3433 Btuh <br /> Volume(ft') 24945 24945 <br /> Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 31610 Btuh <br /> Equiv.AVF(cfm) 91 46 Req. total capacity at 0.85 SHR 2.8 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-036-230-21 Cond 14HPX-036-230-21 <br />� AHRI ref 10258589 Coil CBA27UHE-036-230'`++TDR <br /> AHRI ref 10258589 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 29580 Btuh <br /> Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh <br /> Temperature rise 25 °F Total cooling 34800 Btuh <br /> Actual air flow 1200 cfm Actual air flow 1200 cfm <br /> Air flow factor 0.035 cfm/Btuh- Air flow factor 0.043 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> I Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point= 33°F <br /> Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .�. -�1- wrightsoft� 2017-Sep-2510:54:18 <br /> �� Right-Suite�Unipersal 2017 17.0.23 RSU05714 Page 1 <br /> ...th CBA27UHE AH's\2421 sf ADS template 3 ton.rup Calc=MJS Front Door faces: E <br />