My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19250
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19250
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 10:18:43 AM
Creation date
9/21/2018 10:18:41 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19250
Building Department - Name
LENNAR HOMES LLC
Address
6623 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> . <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3127AB sf ADS Builder Name: LENNAR HOMES 0304 <br /> street: 6623 Silverado Ranch Boulevard Permit oftice: pasco <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner: LENNAR HOMES Jurisdiction: 61160��� <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1772.00 ftZ <br /> 6. Conditioned floor area above grade(ft� 3127 b.Knee Wall(Vented) R=30.0 174.00 ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 302.4 <br /> a. U-Factor: Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 117.00 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 86.67 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4.220 ft. <br /> Area Weighted Average SHGC� 0.303 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (3181.0 sqft.) Insulation Area EF 0.950 <br />' a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ft� None <br /> c.other(see details) R= 260.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.117 Total Proposed Modified Loads: 90.98 pASS <br /> Total Baseline Loads: 92.81 <br /> I hereby certify that the plans and specifications covered by Review of the plans and T�:ST <br /> � �� �r <br /> this calculation are in compliance with the Florida Energy ' specifications covered,by this y� _ 4�pfi_ <br /> Code. ! calculation indicates compliance �'��,,,''� `-_��a�.���,�s+. . <br /> �ave Wl{'l�� With the Florida Energy Code. �= rrr�r;��'%%�;;r�,°;•��`�=��ti O <br /> PREPARED BY: � - ''' """ <br /> Before construction is completed � ��, �� 0 <br /> DATE: this building will be inspected for � �,• i`-- ,�. <br /> compliance with Section 553.908 * � g= :- �. <br /> I hereb certi that this buildin as desi ned,' in com liance Florida Statutes. +�.- <br /> Y fY 9, 9 P '�r -:, <br /> with the Florida Energy Code. _ G'O,py`,���__ <br /> OWNER/AGENT: BUILDING OFF�C�L: <br /> DATE: > > DATE: <br /> - Compliance requires certification by t e air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. <br /> 8/10/2017 1 14 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />� 1 <br />