Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19250
Building Department - Name
LENNAR HOMES LLC
Address
6623 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 , <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 3127AB sf ADS Builder Name: LENNAR HOMES 0304 I� <br /> street: 6623 Silverado Ranch Boulevard Permit o�ice: pasco <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner. LENNAR HOMES Jurisdiction: 611600 I <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft� <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R- ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1772.00 ft <br /> 6. Conditioned floor area above grade(ft� 3127 b.Knee Wall(Vented) R=30.0 174.00 ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ft� <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 302.4 <br /> a. U-Factor: Dbl,U=0.54 162.68 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 117.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor• Dbl,U=0.56 86.67 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighfed Average Overhang Depth: 4.220 ft. <br /> Area Weighted Average SHGC: 0.303 14.Hot water systems _ <br /> 8. FloorTypes (3181.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ftZ None <br /> c.other(see details) R= 260.00 ftZ 15.Credits Pstat <br /> Glass/FloorArea: 0.117 Total Proposed Modified Loads: 90.98 pASS <br /> Total Baseline Loads: 92.81 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'tk�cST,,�7,� :_ <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' ��S'� = p <br /> Code. calculation indicates compliance �.�+�,,,'''� r`"����.,� <br /> � "' a �'d' <br /> �aV2 �G�l�rGl� �,,�, _ �:,�:�,,, � <br /> with the Florida Energy Code. �� _rnrr,�. � �'==�'�';�+`=rti � l <br /> PREPARED BY: Before construction is completed `� •• <br /> DATE: this building will be inspected for .� .-I��'��.-�` ~ � <br /> compliance with Section 553.908 *, - �� ��'�'�:=- : � <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. , ` ,�;- ' <br /> Y fY 9, 9 P ='� -."` �.s <br /> with the Florida Energy Code. "G'Op�yyr;.�� _ <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: " <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. <br /> 8/10/2017 1:14 PM EnergyGauge RO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />� <br />