My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19254
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19254
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 10:21:40 AM
Creation date
9/21/2018 10:21:39 AM
Metadata
Fields
Template:
Building Department
Company Name
RUBY TUESDAY
Building Department - Doc Type
Permit
Permit #
18-19254
Building Department - Name
NATIONAL RETAIL PROPERTIES LP
Address
7909 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Commercial ' EPA Certified <br /> Refrigeration State Certified <br /> Air Canditioning CFESA Certified <br /> Heating Systems �� Established in 1906 <br /> Kitchen Equipment 24hr Emergency Service <br /> Ventilation Systems TbYC SER Y/CES Parts and Equipment Sales <br /> Beverage Equipment Ice Machine Sales and Leasing <br /> PROPOSAL <br /> Customer: Ruby Tuesday Corp(241466) Date: 1/25/2018 <br /> Ruby Tuesday#7178 TPA(7178) Quote#: 53068.1 <br /> 7909 Gall Bivd. <br /> Zephryhills, FL 33541 Customer PO: 92659172 <br /> Work Order: 5910402 <br /> Project: Replace RTU 3& RTU 4gas packs with Is Equipment Running: Partially <br /> client supplied equipment. Age of Equipment: 14 <br /> Condition of Equipment: Recommend Replacement <br /> We propose to furnish the materials and/or perform the work described below: <br /> RTU 3 YSC102A3RLA1 LBOAOA2A000B0, serial 449101443L, 8.5 ton gas pack, and RTU 4 YCD150D3LOBB, serial <br /> 450100899D, 12.5 ton gas pack. Our technician found these RTUs have failed gas heating components, are in poor <br /> condition, and recommends that they be replaced. We will remove the old equipment for disposal, install the new client <br /> supplied RTUs, install a new supply smoke detector(per unit), return smoke detector(per unit)and key station (per <br /> unit), install tie downs, startup, and test for proper operation. The existing equipment has internal disconnects -this <br /> quote includes an electrical subcontractor to install a new external disconnect on each unit.The new equipment <br /> disconnects will be connected to the existing main electrical runs and main breakers.The new equipment will be <br /> connected to the existing control wiring, thermostats, and gas supply. Quote includes mechanical permit, electrical <br /> permit, crane rental, electrical subcontractor, freight for materials, labor, startup, and final inspection. Non specified <br /> electrical upgrades, site upgrades, roofing work, and mechanical drawings required to pull a permit or pass inspection <br /> are not included in this quote.The diagnosis is included in this quote. Note:This quote is priced to install both units <br /> same day with three techs on site.This will be a long day incurring round trip charges. <br /> We have included the following: <br /> • All labor during regular business hours <br /> • Delivery of materials and equipment to the job site <br /> • Final adjustment and calibration of equipment <br /> • Crane rental <br /> • Electrical subcontractor-2 disconnects <br /> • Permits &final inspection. <br /> • Both units installed same day. <br /> We have not included: <br /> • Any work not specifically stated in the proposal <br /> • Next day or Express shipping is not included <br /> • Fire alarm panel work <br /> • Circuit breakers <br /> • Mechanical drawings <br /> • Each unit installed on separate days. <br /> All for the sum of: thirteen thousand eight hundred four dollars and forty-five cents <br /> $13,804.45 <br /> This quote is good for 30(thirty)day(s). <br /> Quote#53068�Revision#1 <br /> 13937 Lynmar Blvd'Tampa,FL 33626'Phone(813)884-0037'www.twcservices.com � <br /> Page 1 of 2 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.