Laserfiche WebLink
4. SIGNALING LINE CIRCUITS ' ` <br /> Characteristics of signaling line circuits connected fo system (see NFPA 72, Table 6.6.1) <br /> Quantity: 2 Style: Y Class: '{; <br /> 5.�►LARM-IMITIATING DEVICES AND CIRCUITS <br /> Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5) <br /> Quantity• 2 style: Y Class: � <br /> 5.1 Manual Initiating Devices <br /> 5.1.1 Manual Pull Stations Number of manual pull stations: � <br /> Type of devices: �Addressable _Conventional _Coded Transmitter _N/A <br /> 5.2 Automatic Initiating Devices <br /> 5.2.1 Area Smoke Detectors Number of smoke detectors: �� <br /> Type of coverage:_Complete area �[ Partial area _Nonrequired partial area _N/A <br /> Type of devices: �Addressable _Conventional _Coded _Transmitter _N/A <br /> Type of smoke detector sensing technology: _lonization x Photoelectric <br /> 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: ✓� <br /> Type of coverage:_Complete area �Partial area _Nonrequired partial area _N/A <br /> Type of devices: _Addressable _Conventional _Coded _Transmitter _N/A <br /> Type of smoke detector sensing technology: _lonization �C Photoelectric <br /> 5.2.3 Heat Detectors Number of heat detectors: � <br /> Type of coverage:_Complete area _Partial area _Nonrequired partial area 3C N/A <br /> Type of devices: _Addressable _Conventional _Coded _Transmitter X N/A <br /> 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: l <br /> Type of devices: �Addressable _Conventional _Coded _Transmitter _N/A <br /> 5.2.5 Alarm Verification Number of devices subject to alarm verification O <br /> Alarm verification on this system is: _Enabled X Disabled _Set for seconds <br /> 6. SUPERVISORY SIGNAL-INITIATING DEVICES AfVD CIRCUITS <br /> 6.1 Sprinkler System Number of valve supervisory switches � <br /> Type of devices: �Addressable _Conventional _Coded _Transmitter _N/A <br /> 6.2 Fire Pump <br /> Type of fire pump: _Electric _Diesel <br /> Type of fire pump supervisory devices: _Addressable _Conventional _Coded _Transmitter �N/A <br /> Fire Pump Functions Supervised <br /> _Fire pump power _Fire pump running _Fire pump phase reversal _Selector in not in auto position <br /> _Engine or control panel trouble _Low fuel <br /> other: N//� <br /> 6.3 Engine-Driven generator: <br /> Type of generator supervisory devices: _Addressable _Conventional _Coded _Transmitter �( N/A <br /> _Engine of control panel trouble _Generator running _Selector switch not in auto position _Low fuel <br /> Other: N/Oa <br /> Page 2 of 4 <br />