Laserfiche WebLink
SMA SB6.0-US Inverter with Hyundai HIS-S290RG Modules ' <br /> � 6.96 kW DC Photovoltaic System Electrical Diagram with (2) Series Strings of 12 Modules <br /> �� � $ 0 <br /> Optional Supply Side Connection <br /> romv�� NEC705.12A s2so _ (12)Hyundai HiS-S290RG <br /> RG #12 290 Watt Modules in series <br /> u <br /> G N M <br /> r� �..�. <br /> g6 bart copocr <br /> GEC (3)p 6 UtiGty meler <br /> THFiNRHWN-2 xoop $290 #�2 <br /> ]I4"PVC conduN � <br /> 6o A tused � RG <br /> disconnectwhh — <br /> 3sar„� �ti�9 M,m���.���p� Hyundai HiSS290RG <br /> ground'ng P�� - � -- -- Module Specifications SMA SB 6.0-US Inverter <br /> dectrode —` —' — — <br /> ^ Pmax:290 W N�ax.lnput DC Voltage: 600 VD <br /> 4)#10 AWG PV Wire 3-R,3-B (1)#6 AWG Bare Copper p Max ISC per string: 18 A <br /> 200A Panelboard with Voc: 38.8 V MPPT Range: 100-550 VDC <br /> 200A Main breaker Vmpp:32.0 V Max Output Voltage:240 VAC <br /> (4)#10 AWG THHN(fHWN-2 ISC: 9.7 A <br /> 2-B,2-R Im 9.1 A Max Output current: 25 A(AC) <br /> O3 pp' AC Nominal Power:6000 Watts <br /> 200A-2 (1)#8 AWG THHN/THWN-2 .C.Voltage: -0.30%/C <br /> O 1-G <br /> 10 OOZ 3/4"EMT,FMC(inside structure Notes: All work to meet or exceed NEC 2011 <br /> LFNC,PVC(outside structure) 1 Junction box to be located within the array boundary. Junction box must be minimum Nema 3R UL listed <br /> 690.31E enclosure.Free air conductors must be installed in raceway if readily accessible as per 690.31(A). <br /> 71 Nema 3R <br /> 35A/2 Junction 2 The minimum volume of the Nema 3R enclosure for the transition of PV wire to THWN-2 wire shall be <br /> � BaX 42 cubic inches. Heyco 5 wire Masthead gland seals or similar connector are required as strain relief <br /> j for PV wire into Nema 3R junction box at array. <br /> 1 � � SMA Sunny Boy 6.0-US 3 Interconnection with 35 Amp 2 pole OCPD via 2011 NEC 705.12(D)(2)Load Side Connection. The 35 A <br /> �'� Transformerless Inverte <br /> backfed breaker must be located at the opposite end of the bus from the 200 A main supply rea er <br /> — ! o� with integrated DC 4 The required PV Backfed breaker plus the main breaker rating must be less than or equal to 120%of <br /> existing n A� disconnect <br /> grounding i 4 � the Main service bus rating. 705.12(D)(2) <br /> electrode • `� 5 Optional Supply Side connection via 705.12A using parallel line taps in a NEMA 3R box(as required) <br /> • � (4)#8 AWG THHN/THWN- using N51 IPCS4002, Ilsco IPC-KUP-L or NSI Tork IPLD 3/0-3 Multi-Tap Connector or equivalenk <br /> � ' 1-B,1-R,1-W,1-G <br /> � � s PV service disconnecting means for"optional"supply side connection must have neutral/EGC bond <br /> i 3/4"EMT,FMC,LFNC, <br /> b -\b � � or PVC within and must be listed as"suitable for use as service equipment" 230.66 <br /> 7 The fuses in the disconnect for the"supply side"option must be rated to handle the maximum short- <br /> Y 4 <br /> •-� circuit current available at the supply terminals.110.9,110.10 Over-current protection for the supply side <br /> � (4)#8 AWG THHN/THWfU-2 connected conductors shall be located within 10 feet of the connection to the service. 705.31 <br /> -!' g Grounded conductor shall be routed with ungrounded conductors to PV Service disconnecting means as <br /> ? 1-B,1-R,1-W,7-G per 250.24(C)if"Supply Side"option is used. � <br /> 3/4"EMT,FMC,LFNC,or PV s For"Supply Side option" Continuous or irreversibly spliced Grounding Electrode Conductor lnstalled � <br /> per 250.24(D). Grounding Electrode Conductor shall be specified as per 250.64 and sized per 250.66 <br /> 10 The following label is required on meter can and main panelboard"Services fed from dual power sources <br /> 13 Utility and Photovoltaic system" <br /> 60A 240V AC Disconnect with label: �� "PV input Do not relocate this OCPD"label required adjacent to backfed breaker. 705.12(d)(7) <br /> On-site Utility Generation DC Disconnect Label Requirements 12 Bonding of module to rail and module to module accomplished through WEEB washers or self grounding <br /> Disconnect Slivitch(IF REQUIRED BY UTILITY) <br /> Vmpp 384 VDC mid-clamps. <br /> PV AC Disconnect Label Requirements VmaX 500.5 VDC 13 "Warning:DC conductors of this system are ungrounded and may be energized"required on the <br /> Operating Current:25 A Impp 18.2 A DC Disconnect 690.35F <br /> O eratin VoltB e:240 VAC ImBX 24.25 A 14."Warning:Photovoltaic Power 5ource"label required on conduit per 690.31(E)(3)(4) <br /> P 9 9 15. Total voltage drop%for all circuits based on listed conductors is 1.46% <br />