My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19305
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19305
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 7:38:44 AM
Creation date
9/24/2018 7:38:42 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19305
Building Department - Name
LENNAR HOMES LLC
Address
3209 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a mxnimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey requzred before pouring cancrete. <br /> 5. Driveways require a R.Q.W. use permit. All 4 sides of driveway thru.the sidewalk shall have <br /> expansion materiai. <br /> 6. All setbacks shall be met. <br /> 7. Ali property markers sha11 be uncovered and rnarked at tirr�e of first inspection. <br /> 8. All A,D.A. requirements shall be met. <br /> 9. No electric, plumbing, rnechanical, or framing shall be cavered without an inspection and <br /> approval first. <br /> 10. Ail Garages shail comply with section R302.6 of the F.B.C. (Fire Separatian). <br /> 1 l. Appliances shall not be installed in a location where subject to mechanical damage untess <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supparts far A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedroams. F.B.C. M162Q.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 af the F.B.C. <br /> 16. All glazing requirements are to be in accardance with R30$.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F,B.C. <br /> 18. "Green gypsum baard" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all Iocations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarrns will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes a11 <br /> underground plumbing and electric. <br /> 22. All 2Q08 N.E.C. Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 4Q6.11 of the 2008 N.E.0 <br /> 24. In accordance with the Land Development Code, Iats shall be sodded before final at Ieast 10 <br /> feet axound the structure. <br /> ZS.A evpy of the energv cacls shall be with pet•ntit at all times <br /> 26. Conv of final insulation report shall be provided with ne�•mit before finaZ <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 5�'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-Natianal Electric Code (200$) <br />
The URL can be used to link to this page
Your browser does not support the video tag.