Laserfiche WebLink
f � <br /> �FORM R405-2014 ' <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) 000367 2488.2 136.6 256.9 .339 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.5 17.5 kBtu/hr 1 sys#1 <br /> 2 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 2 sys#2 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER: 16 18 kBtu/hr 540 cfm 0.85 1 sys#1 <br /> 2 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ftz <br /> DUCTS <br /> / —Supply— —Return— Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 Attic 6 218.6 ft 2nd Floor 54.6 ft2 Proposed Qn 2nd Floor —cfm 76.5 cfm 0.07 0.60 1 1 <br /> 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Praposed Qn 2nd Floor —cfm 104.4 cfm 0.07 0.60 2 2 <br /> TEMPERATURES <br /> Programable Thermostat:Y Ceiling Fans: <br /> Coolin Jan Feb [ ]Mar A r Ma X Jun X Jul Au X Se Oct Nov Dec <br /> Heatin9 �Jan �Feb [X]Mar ��Apr f �MaY � �Jun 4 �ilul ��Au9 4 �Sep E �Oct f X�Nov �Dec <br /> Ventin Jan Feb [X]Mar A r [ Ma Jun [ Jul Au [ Se [X Oct [X Nov Dec <br /> 7/6/2017 6:48 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 <br />