My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19305
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19305
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 7:38:44 AM
Creation date
9/24/2018 7:38:42 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19305
Building Department - Name
LENNAR HOMES LLC
Address
3209 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, . � � , . <br /> Manual S Compliance Report Job: 2575A1sf ADS2017 <br /> Date: 1013012017 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - • s <br /> For: Lennar Homes <br /> • • • • . <br /> Design Conditions <br /> �Outdoor design DB: 91.3°F Sensible gain: 11336 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.3°F Latent gain: 1233 Btuh Entering coil WB. 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 12569 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br />� ' <br /> Manufacturer s Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-01&230-21+CBA27UHE-018-230*++TDR <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 135°/a of load <br /> Latent capacity� 2700 Btuh 219% of load <br /> Total capacity: 18000 Btuh 143% of load SHR: 85% <br /> • � • <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss• 16249 Btuh Entering coil DB• 69.6°F <br /> Indoor design DB. 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230'`++TDR <br /> Actual airflow: 600 cfm <br /> Output capacity: 17500 Btuh 108% of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 4.5 kW 94% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. <br /> � wri htsoft° zo,�-ooc-so oa:,�:os <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page� <br /> � ...BA27UHE AH's�2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.