My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19306
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19306
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 7:39:53 AM
Creation date
9/24/2018 7:39:50 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19306
Building Department - Name
LENNAR HOMES LLC
Address
3197 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summa Job: 2889A1 sf ADS <br /> J � Date: 10130/2017 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> - i <br /> I <br /> � <br />� ' • • • <br /> I <br /> For: Lennar Homes <br /> N otes: 2017 <br /> � - • • • <br /> Weather: Tampa InternationalAP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 92 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 17 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 21080 Btuh Structure 17627 Btuh <br /> Ducts 2020 Btuh Ducts 2360 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 23100 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Inflltl'atlon Equipment sensible load 19987 Btuh <br /> Method simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2502 Btuh <br /> Ducts 403 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1793 1793 Equipment latent load 2905 Btuh <br /> Volume(ft') 16024 16024 <br /> Air clianges/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 22891 Btuh <br /> Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.0 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024-230-21 Cond 14HPX-024-230-21 <br /> AHRI ref 10258598 Coil CBA27UHE-024230*++TDR <br /> AHRI ref 10258598 <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.035 cfm/Btuh Air flow factor 0.040 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Capacity balance point= 33°F <br /> Backup: <br /> Input= 6 kW, Output=22126 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .�. wri htsoft9 2017-Oct-30 09:34:45 <br /> �� g Right-SuiteQ31 Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...BA27UHE AH's\2S89A sf template ADS 1.5-2ton.rup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.