Laserfiche WebLink
f � <br /> FORM R405-2014 ` <br /> CEILING <br /> # Ceiling Type Space R-Value Ins Type Area Framing.Frac Truss Type <br /> 1 Under Attic(Vented) 2nd Floor 30 Blown 1109 ftZ 0.11 Wood <br /> 2 UnderAttic(Vented) 1st Floor 30 Blown 1064 ftZ 0.11 Wood <br /> 3 Knee Wall(Vented) 2nd Floor 30 Batt 140 ft2 0.11 Wood <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w <br /> 1 N=>NE E�erior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 58 8 8 502.7 ftZ 0 . 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul 1 st Floor 4 0999 34 8 8 294 7 ftZ 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ftz 0 0.600000 0 <br /> _ 5 N=>NE Garage Frame-Wood ist Floor 11 19 9 S 8 171.2 ftZ 0 0.01 0 <br /> _ 6 W=>NW Garage Frame-Wood 1st Floor 11 18 6 8 8 160.3 ft2 0 0.01 0 <br /> 7 N=>NE 6cterior Frame-Wood 2nd Floor 11 40 8 320.0 ftZ 0 0.600000 0 <br /> - 8 E=>SE Exterior Frame-Wood 2nd Floor 11 29 6 8 236.0 ft2 0 0.600000 0 <br /> ' 9 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 <br /> � 10 W=>NW Exterior Frame-Wood 2nd Floor 11 29 9 8 238.0 ftZ 0 0 0.600000 0 <br /> 11 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ftZ 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated 1 st Floor None .2 3 6 8 20 ftZ <br /> 2 W=>NW Wood 1 st Floor None .4 2 8 6 8 17.8 ftZ <br /> ' � WINDOWS <br /> Orientation shown is the entered orientation =>)chan ed to Worst Case. <br /> / Wall Overhang <br /> �� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 16.0 ftz 1 ft 0 in 13 ft 4 in None None <br /> 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 48.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 4 S=>SW 11 Metal Low-E Double Yes 0.56 0.32 33.3 ftZ 2 ft 0 in 1 ft 2 in None � None <br /> 5 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 � 32.0 ftZ 1 ft 0 in 0 ft 4 in None None <br /> 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 4 in None None <br /> 7 W=>NW 10 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 0 ft 4 in None None <br /> 8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 3 ft 5 in Drapes/blinds None <br /> 10/13/2017 7�06 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 <br />